32
3.2.10 Setpoint Deviation Menu
Figure 3.8 Flow Chart for Setpoint Deviation Menu
ENTER SETPOINT DEVIATION MENU:
Press
a
1)
Press
a
, if necessary, until
CNFG
prompt appears.
Press
d
2)
Display advances to
INPT
Input Menu.
Press
a
3)
Press
a
, if necessary, until Display advances to
SP.DV
Setpoint Deviation Menu.
SETPOINT DEVIATION ENABLE/DISABLE SUBMENU:
Press
d
4)
Display advances to Setpoint Deviation
ENBL
Enable or
DSBL
. Disable Submenu and flashes the previous selection.
Press
b
5)
Scroll through the available selections:
ENBL
or
DSBL
.
Press
d
6)
Display shows
STRD
stored message momentarily and then
advances to the next menu item.
Setpoint Deviation
menu, if “enabled”, allows changes to Setpoint 1 to be made
automatically to Setpoint 2. This mode is very helpful if the Process Value
changes often. In Setpoint Deviation Mode, set SP2 a certain number of counts
away from SP1 - this relation remains fixed when SP1 is changed. For instance:
Setting SP1=200 and SP2=20 and enabling
SP.DV
means that the absolute
value of SP2=220. Moving SP1 to 300, the absolute value of SP2 becomes 320.