![background image](http://html1.mh-extra.com/html/omega/ild-big-display/ild-big-display_user-manual_4000915049.webp)
45
NETWORK AND
COMMUNICATIONS
(Optional -C24, -C4EI, not available
with excitation)
Ethernet:
Standards Compliance
IEEE 802.3 10Base-T
Supported Protocols:
TCP/IP, ARP,
HTTPGET
RS-232/RS-422/RS-485/MODBUS:
Selectable from menu; both ASCII
and modbus protocol selectable from
menu. Programmable 300 to 19.2 K
baud; complete programmable setup
capability; program to transmit
current display, alarm status,
min/max, actual measured input
value and status..
RS-485
Addressable from 0 to 199
Connection
Screw terminals
ALARM 1 & 2
Programmable to Display Color Change
Operation
High/low, above/below, band,
latch/unlatch, normally open/normally
closed and process/deviation; front
panel configurations
EXCITATION
(optional in place of
Communication)
5 Vdc @ 40 mA
10 Vdc @ 60 mA
INSULATION
Power to Input/Output
2500 Vac per 1 minute test
(RS-232/485, Input or Output)
Between Inputs
500 Vac per 1 minute test
Approvals
See CE Approval Section
GENERAL
Power
100-240 Vac +/-10%, 50/60 Hz
22.5 W
Environmental Conditions
0 to 40°C (32 to 104°F),
90% RH non-condensing
Installation Category
II per EN61010-1
Equipment Class
II per EN61010-1
Pollution Degree
2 per EN61010-1
Protection
NEMA-4x (IP65) front bezel
Dimensions
Refer to Quickstart Specifications.
Weight
Refer to Quickstart Specifications.