All devices connected to the Layer N Gateway will appear, including those that are offline. The readings from offline units
will display NaN. For more information on how to navigate OEG, refer to the OEG Software User’s Manual.
Note:
The maximum reading interval is 120 seconds for Layer N Gateway. After switching to
Enterprise Mode
from
Cloud Mode
, the Layer N Gateway device should be manually powered off and on again. Omega Enterprise
Gateway should also be restarted from the Windows OS Services application. In the future, if users will be
using the Layer N Cloud service, they must navigate to the Gateway web UI again to uncheck the
Turn off
Cloud Registration
box.
6.1.1
Configuring Sensing Devices after Pairing with OEG
If a sensing device paired wirelessly or wired directly to the Layer N Gateway has been configured or
modified after the Layer N Gateway has been added to OEG, the user must reboot the Layer N Gateway and
restart the OEG software to sync with the configuration made to the connected device.