6
Menu Configuration Displays
46
SECTION 6. MENU CONFIGURATION DISPLAYS (Continued)
Table 6-1. Menu Configuration Displays (Continued)
(Defaults in Bold and Italics)
MENU
∂
TARE
ß
NT/GRS
Reading Configuration
R.1=
R.1=R
(Ratiometric Reading)
R.1=N
(Non-ratiometric reading)
RD.CF
R.2
=
R.2=0
(1 µV resolution for unipolar
& 5 µV resolution for bipolar)
R.2=1
(2 µV resolution for unipolar
& 10 µV resolution for bipolar)
R.2=2
(3 µV resolution for unipolar
& 15 µV resolution for bipolar)
R.2=3
(5 µV resolution for unipolar
& 25 µV resolution for bipolar)
R.2=4
(10 µV resolution for
unipolar & 25 µV resolution
for bipolar)
Note:
3 µV resolution means if
your input is 0-30 mV, at 30 mV
the display shows 9999.
R.3
=
R.3=F
(Filtered value)
R.3=U
(Unfiltered value)
R.4
=
R.4=G
(Gross/Net Display)
R.4=P
(Peak Display)
Show input choices:
GRN
(Green)
Display Color Selection
RED
(Red)
COLR
AMBR
(Amber)
Setpoint 1 Configuration
S.1
=
S.1=A
(Active above)
S.1=B
(Active below)
S1.CF
S.2
=
S.2=U
(Unlatched)
S.2=L
(Latched)
S.3
=
S.3=N
(Net Reading)
S.3=G
(Gross Reading)
Setpoint 2 Configuration
S.1
=
S.1=A
(Active above)
S.1=B
(Active below)
S2.CF
S.2
=
S.2=U
(Unlatched)
S.2=L
(Latched)
S.3
=
S.3=N
(Net Reading)
S.3=G
(Gross Reading)
Summary of Contents for DP25B-S