background image

 

the  measured  pH  value  of  the  solution  is  lower  than  the  value  of  High 

alarm,  furthermore  lower  than  the  hysteresis,  the  AH  alarm  light  will  be 

turned off and the high relay (N/O) open. 

(3)    AL  alarm  light

Under  the  conditions  of  setting  low  alarm,  when  the 

measured pH value of the solution is lower than the value of low alarm, the 

AL alarm light will be turned on and the low relay (N/O) close; When the 

measured  pH  value  of  the  solution  is  higher  than  the  value  of  low  alarm, 

furthermore  higher  than  the  hysteresis,  the  AL  alarm  light  will  be  turned 

off and the low relay (N/O) open. 

(4)    SET indicator light, the light will be turned on when entering the setting 

state. 

(5)    uS/cm  indicator  light.  When  the  light  is  lit  in  the  measurement  state

means the measured value is conductivity, and unit is uS/cm. 

(6)    M

Ω·

cm indicator light. When the light is lit in the measurement state

means the measured value is resistivity, and unit is M

Ω·

cm. 

(7)   

 indicator light. When the light is lit in the measurement state

means the 

measured  value  is  Temperature;  When  the  light  is  lit  in  the  setting  state, 

means the input parameter is Temperature. 

(8)   

MENU

 

Press the

 

MENU

 

key to enter or exit the setting state.

 

(9) 

 

 

 

In setting state, using the

   

   

key the user can cycle through the 

front menu. To adjust a value, the

 

   

   

key is used to select a digit

 

(10) 

   

 

In the setting state, using the

 

 

   

key the user can cycle through 

the next menu. To adjust a value, the

 

 

   

key is used to increment the 

digit

.

 

(11)

   

ENTER

   

key is the enter button to confirm enter the menu and store 

the setting parameters. 

Summary of Contents for CDTX-111

Page 1: ...e mail info omega com For latest product manuals www omegamanual info Shop online at omega com User sGuide CDTX 111 Conductivity Monitor MADE IN CHINA...

Page 2: ...3 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide www omega com info omega com The information contained in this document is believed to be correct but OM...

Page 3: ...4 3 4 Connection 6 4 SETTING AND OPERATION 7 4 1 Switch Measuring and Setting Mode 7 4 2 Menu Structure 7 4 3 Parameter Setting and Operation 9 4 3 1 Set Alarm 9 4 3 2 Calibration 11 4 3 3 Set Current...

Page 4: ...tion 4 Manual or Automatic buffer adjustment 5 Restore factory setting function is available 6 Galvanic separation between inputs and outputs and supply voltage 7 Different input for excellent noise r...

Page 5: ...ounting version is designed to be flush mounted and sealed in a square cut out in a panel and is held in place with the two screw clamps provided 3 1 Dimensions Figure 2 overall dimensions panel mount...

Page 6: ...digital Monitor displayed the measured values and can also be displayed prompt function parameter values and error codes in interactive 2 AH alarm light Under the conditions of setting high alarm whe...

Page 7: ...cm indicator light When the light is lit in the measurement state means the measured value is conductivity and unit is uS cm 6 M cm indicator light When the light is lit in the measurement state mean...

Page 8: ...re 5 Spare 6 Ground 7 Power supply terminal Connect AC110 220V 8 Power supply terminal Connect the power supply phase 9 Conductivity sensor line A red 10 Conductivity sensor line A yellow or white 11...

Page 9: ...tion check the connection is correct then put the sensor into the test solution preheat for 10 minutes you can perform the following operations 4 1 Switch Measuring and Setting Mode Instrument has two...

Page 10: ...end value budongzuodai budongzuodai Set conductivity start value for current output Set conductivity end value for current output budongzuodbudongzuodai Set temperature start value for current output...

Page 11: ...01 budongzuodbudongzuodai Select cell constant k 0 10 budongzuodbudongzuodai Select cell constant k 1 00 Display temperature value budongzuodbudongzuodai Display resistivity value budongzuodbudongzuo...

Page 12: ...to 2000 uS cm When it decreases through 2000 uS cm the alarm turns off Some applications may demand that the alarm turns off at a different value for a high alarm this would be value lower than the al...

Page 13: ...of the instrument can be effected by seasonal variations in the measured effluent however only knowledge of the application can determine the re calibration interval required 4 3 2 1 CAL conductivity...

Page 14: ...isplay value as same as the conductivity value of the solution press ENTER to store the calibration data This value is stored even after power failure and return to the setting state 4 3 2 2 C0 C100 t...

Page 15: ...to store and return to the setting state 4 3 2 4 C1 C set temperature compensation coefficient The temperature compensation coefficient is different for each type of solution so the temperature compe...

Page 16: ...tting Range 0 100 4 3 3 Set Current Output CDTX 111 has one 4 20mA current output The user can select the input source conductivity or temperature And the current output can be set work over the whole...

Page 17: ...tch it then Press ENTER to store and return to the setting state Code Content Direction FSIS Current output start value 4 00 20 00 mA FSIE Current output end value 4 00 20 00 mA FSI The input for the...

Page 18: ...ht also changes to indicate that the display state changes The corresponding parameters in the setting also will automatically change NOTE The sensor should be changed when switch the measurement mode...

Page 19: ...used in industry province with all kind of conductivity monitor 6 1 Sensor Features High sensitivity and accuracy with reliability and durability Stainless material Quickly response within two second...

Page 20: ...Conductivity Medium Pure Water Water Water cell constant 0 01 0 1 1 0 Range 0 18M or 0 19 99us cm 0 199 9us c m 0 1999 us cm Temp range 0 60 0 60 0 60 Temperature Measurement 0 60 0 60 0 60 Compensati...

Page 21: ...iler water 0 05 1 us cm Deionized water 0 5 us cm Distilled water 0 1 10 us cm Softened water 1 80 us cm Mineral water 10 us cm Beverages 0 5 1 ms cm Waste water 0 9 9 ms cm KCL Solution 1 4ms cm Brin...

Page 22: ...or a short time then rinse with pure water that maintain the sensor surface clean 3 Sensors cable is a dedicated cable can not be replaced or extended by users self 4 Instrument should be installed in...

Page 23: ...se shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OME...

Page 24: ...bine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industri...

Reviews: