4.3.9.1 End Device Parameters (continued)
Device Name:
Name of this End Device.
Update (Seconds):
How often this End Device is sending its data to the
Receiver. The default shown “update second” is 0 seconds. This update
corresponds to the sampling rate configured by using the Configuration Wizard.
For detailed steps on how to configure the sampling rate, please refer to
Section
4.1 of the UWTC Manual
.
For a more accurate success rate and lost packet information, it is
necessary to keep the “Update” time, the same as the “Sampling Rate”
of the UWTC End Device.
Sensor 1
This is the field to modify the parameters for the external sensor (process).
Remote Display Format:
Remote display format is for Server Type
continuous
mode. It basically defines the way the data is shown on a Remote Display. The
default value is 0000000F. This means that the value will be displayed up to 7
digits, followed by the unit of F, for a maximum of 8 characters. Any letters before
and/or after the number will be displayed accordingly. Keep in mind that the
displayed letters will take away from the available 8 characters.
Make sure that you have enough 0’s to display the entire temperature
value. Any extra 0’s will be ignored.
If there is no temperature unit,
then the unit will read from the
“Input” menu if the Controller
Setup.
Remote End Char:
The default value is
0D (Hex representation of <CR>). This
means that the Meter sends <CR> after
each temperature reading. This will be
done either in
Continuous
or
Command
mode.
This is how the data will appear on the
host with 0D assigned:
T75F
T74F
If the end character for instance is 20
(Hex representation of space), the data
will then appear as:
T75F T74F
If nothing is set for the “Remote End
Char” field, the Meter will then forward
the data to the LAN with no characters
followed.
57
Engr Lab
75F
75F
Server Room
75F
77F
Clean Room
73F
75F
Engr Lab
75F
75F
Server Room
Tera Term - 206.29.25.27 VT
File Edit Setup Control Window Help
Figure 4.24
Remote Display