AWS-C Installation and operating manual 

 

 3 

Safety instructions 

 

 

Depressurize the system before carrying out any work on the piping. 

 

Installation and maintenance work may only be carried out when the device is 

not under pressure. 

 

Installation and maintenance work may only be carried out by trained and 

experienced stuff.   

 

Disconnect power supply before installation or any maintenance work. 

 

Electrical work must always be carried out by qualified electrician. 

 

Do not exceed max. operating pressure or operating temperature range (see 

data label). 

 

Do not use the device in hazardous areas with potentially explosive 

atmospheres. 

 

Use original spare parts only. 

 

Use the device for the appropriate purpose only. 

 

 Appropriate use 

AWS-C  tyre inflation controller is intended exclusively for the following purpose: 

 

Indication of pressure in tyres/pneumatics 

 

Correction of pressure in tyres (fill/release pressure) 

 

Any other form of use or one going beyond this shall be considered as inappropriate. We 

shall have no liability whatsoever for any damage incurred as a result. 

 

 

Summary of Contents for AWS-C

Page 1: ...nual AWS C Tyre inflation controller Please read the following instructions carefully before installing tyre inflation controller service Trouble free and safe operating of the unit can only be guaran...

Page 2: ...4 Outlet connection Push connection 8 1 4 Resolution for pressure set 0 1 bar Target pressure set range 0 5 do 9 5 bar Measuring range 0 do 9 9 bar Accuracy 15 C do 25 C 75 mbar Accuracy 20 C do 45 C...

Page 3: ...out by qualified electrician Do not exceed max operating pressure or operating temperature range see data label Do not use the device in hazardous areas with potentially explosive atmospheres Use orig...

Page 4: ...gnal 9 Silencer Exhaust 3 Button 10 Outlet connection for compressed air 4 Button 11 Inlet connection for compressed air 5 Button manual start 12 Audible signal 6 Mounting bracket 13 Relay cable gland...

Page 5: ...e of the controller Connect Inlet connection picture 1 with source of compressed air Connect outlet connection picture 1 with tyre inflation hose Connect the controller to the el Electrical work must...

Page 6: ...ntroller has three modes Sleep mode Set target pressure mode Inflation pressure correction mode SLEEP MODE When controller is not active no button is pressed for more than two minutes it goes to sleep...

Page 7: ...ed to value 8bar 6 5bar or 5bar For limitation please contact manufacturer After target pressure is set user can connect hose to the tyre and inflation will start automatically unless pressure in the...

Page 8: ...tyre and controller will automatically switch to set target pressure mode If next tyre is inflated within 2 minutes target pressure value remains the same as it was for previous inflation Attention To...

Page 9: ...on combination Press and hold than additionally press and hold While both buttons are being pressed you can see settings After buttons are released controller goes back to set target pressure mode Pic...

Page 10: ...essure in the tyre An error is detected Button is pressed Correction is successful Show actual pressure in the tyre Target 0 0bar Hose is disconnected Button pressed Button is pressed Error message Ac...

Page 11: ...anual 11 Settings and operating data download To change settings or download operating data please contact manufacturer Manufacturer can change settings or download operating data with service network...

Page 12: ...ulty solenoid valve Dirt in the solenoid valve Check connections Call supplier or service Warranty exclusion The guarantee shall be void if The installation and operating manual was not followed with...

Reviews: