Omec PL.06.00 Instruction, Use And Maintenance Manual Download Page 9

 
 

 

 
 
By  keeping  pushed  one  of  the  two  keys  (

  or 

) for  a  time  shorter  than  2  seconds,  the  change 

of parameter will be by one step corresponding to 1 minute a press. 
 
For  a  rapid  change  the  operator  has  to  keep  one  of  the  two  keys  (

  or 

)  pushed  for  a  time 

longer than 2 seconds. In this case the change of parameter will be by 10 steps correspondent to 
10 minutes a second until the release of the key. 

 

Press key START/STOP to confirm entry. 
 
In  this  specific  case,  after  having  set  hours  and  minutes,  the  time  in  hours  and  minutes 
corresponding  to  the  time  to  go  to  the  start  of  the  cycle  will  appear  on  the  display.  This 
value is shown as countdown to start-up time. 
 
For  all  duration  of  timig,  the  small  dot  among  the  four  numbers  flashes  and  the  red  led  of 
START/STOP key stays on. 
 

3.5.1  WORKING CYCLE 

 
This  cycle  begins  after  having  programmed  the  start-up  (see  chapter  6),  thus,  after  having 
pressed  the  START/STOP  key  (immediate  switching  on)  three  consecutive  times  or  after  the 
programmed time is over (deferred switching on). 
 
When  the  cycle  is  started  up,  a  beep  warns  the  operator  of  the  switching  on  from  the  TIMER 
phase to working phase. 
 
The programmed temperature followed by the true temperature of water in the polymerization tank 
will be shown on the display for few seconds. 
 

The  orange  led  of  START/STOP  key  stays  on  until  the  temperature  set  is  reached.  The 

 

orange  led  of  activated  heating  element  lights  up  and  indicates  the  power  delivery  to  heating 
element. 
 
When  the  temperature  set  on  the  display  is  reached  the  time  holding  value  set  for  the  running 
phase  followed  by  the  real  temperature  of  the  water  inside  the  tank  will  be  shown  on  the 
display just for a few seconds. 
 
The  green  led  of  the  START/STOP  key  will  remain  on  for  all  duration  of  the  time  set;  the  

  orange  led  of  activated  heating  element  stays  on  and  indicates  the  power  delivery  for 

keeping up temperature to the heating element.  
 
A beep notifies the operator on each passage from one phase to another. 
 
Now the polymerizing unit passes to phase no. 2. 
 
The temperature set followed by the real temperature of the water inside the tank appear on the 
display for few seconds. 
 

The orange led of the START/STOP key stays on until the temperature set is reached, the 

 

orange  led  of  activated  heating  element  lights  up  and  indicates  the  power  delivery  to  the 
heating element. 
 
When the temperature set is reached, a beep notifies the operator. At the same time the holding 
value set for the running phase followed by the real temperature of water in the tank or by the 
word “FULL” will be shown on the display just for a few seconds. 
 

The  green  led  of  the  START/STOP  key  remains  on  for  all  duration  of  the  time  set;  the   

 

orange  led  of  heating  element  stays  on  and  indicates  the  power  delivery  for  keeping  up 
temperature to the heating element. 
 
When  the  boiling  time  set  is  over,  the  heating  element  stops  working  and  the  word  OFF  appears 
on the display. 

 

3.6.1  INSPECTIONS 

 
IDLE OFF state 

 
On the IDLE-OFF state the following inspections may be done by using the indicated key: 

  :  by  keeping  this  key  pressed  you  can  see  the  temperature  inside  the  polymerization  tank  on 

the display. 

 
 

- Page 7/9 - 

 

Summary of Contents for PL.06.00

Page 1: ...K Machine POLYMERIZING UNIT Type PL 06 00 PL 12 00 O M E C Snc di R CARNEVALE C Via dell Artigianato 3 5 7 I 20835 Muggi MB ITALY Tel 39 039 793740 Fax 39 039 2780689 E Mail export omec snc com omecsn...

Page 2: ...allation 2 9 3 2 1 Picture No 1 2 9 3 2 2 Picture No 2 3 9 3 3 1 Programming of cycle 4 9 3 4 1 Start up programming 6 9 3 5 1 Working cycle 7 9 3 6 1 Inspections 7 9 3 7 1 Power failures 8 9 3 8 1 Wa...

Page 3: ...and not damaged due to bad carrying b Follow carefully the instructions for installing the machine c The OMEC POLYMERIZING UNIT TYPE PL 06 00 PL 12 00 must be used only by a skilled worker and therefo...

Page 4: ...ic equipment has a good earth and that it is in conformity with the 2006 95 EC Low Voltage 3 1 1 INSTALLATION Verify the apparatus has not stood any evident damage during transportation Place the appa...

Page 5: ...lding time 7 Value increasing key 8 Value decreasing key 3 2 1 PICTURE NO 2 3 3 1 PROGRAMMING OF CYCLE To program a cycle follow correctly and as in the indicated order the instructions below Turn on...

Page 6: ...never to set a value lower then 13 otherwise the heating will be too slow while setting this value always consider the quantity of water inside the tank the more water there is in the tank the slower...

Page 7: ...n sequence If the operator has set FULL as temperature value boiling temperature then the words FULL max speed will appear on display In this case the speed increase is automatically set at FULL max v...

Page 8: ...perator immediate switching on deferred switching on During programming of start up the red leg of key flashes intermittently Immediate switching on Polymerizing unit on OFF press the START STOP key F...

Page 9: ...erature set on the display is reached the time holding value set for the running phase followed by the real temperature of the water inside the tank will be shown on the display just for a few seconds...

Page 10: ...in phases no 1 and no 2 When power returns two cases may present If the power has failed for a short time and the water temperature has not decreased the polymerizing unit will run again all the progr...

Page 11: ...d do not put cable in places where it can be stepped over In case of extended inactivity disconnect the electrical cable Before any transportation always empty the tank and use the original packaging...

Reviews: