Omec PL.06.00 Instruction, Use And Maintenance Manual Download Page 7

 
 

 

 
 
For  a  rapid  change  the  operator  has  to  keep  one  of  the  two  keys  (

  or 

)  pushed  for  a  time 

longer than 2 seconds. In this case the change of parameter will be by 10 steps correspondent to 
a 10 minutes a second until the release of the key.  
 
In  the  case  a  value  equal  to  00.00  is  set,  the  time  of  preheating  is  not  included  and  the 
polymerizing unit will pass directly to phase no. 2 after having reached the temperature. 
 

Press key 

 to confirm data entry and pass to programming of phase no. 2. 

 
PROGRAMMING OF BOILING (PHASE NO. 2) 

 
The words “Ph.2”, “°C” and the last programmed boiling temperature value will appear in sequence 
on the display. 

The red led of 

 key will start flashing intermittently during all boiling program. 

 
The  change  of  this  parameter  (programming  range  Phase  no.  1  temperature  /  FULL=boiling 

temperature) is done by using 

 key (to increase value) and 

 key (to decrease value). 

 
By keeping pushed one of the two keys (

 or 

) for a time shorter than 2 seconds, the change of 

parameter will be by one step corresponding to 1 °C a press. 
 
For  a  rapid  change  the  operator  has  to  keep  one  of  the  two  keys  (

  or 

)  pushed  for  a  time 

longer than 2 seconds. In this case the change of parameter will be by 10 steps correspondent to 
a 10 °C a second until the release of the key. 
 
To make boiling, set the temperature on FULL. 
 

Press 

 key to confirm entry. 

 
If the operator has set a temperature lower or equal to 99°C then the word “rAtE” and the last 
programmed speed increase value will appear on display in sequence. 
 
If  the  operator  has  set  FULL  as  temperature  value  (=boiling  temperature)  then  the  words  FULL 
(=max.  speed)  will  appear  on  display.  In  this  case  the  speed  increase  is  automatically  set  at 
FULL (max value). 
 
In case the temperature of phase no. 2 is set on FULL (=boiling temperature) the speed increase 
is  automatically  set  on  FULL  which  means  the  max.  programmable  speed  (heating  element  always 
on). 
It  is  possible  to  set  an  increase  speed  different  from  FULL  only  if  the  set  value  of  the 
temperature set during phase no. 2 is lower or equal to 99 °C. 
 

The modification of this parameter (programming range 0/FULL=max speed) is done by using 

 key 

(to increase value) and 

 key (to decrease value. 

 
By keeping pushed one of the two keys (

 or 

) for a time shorter than 2 seconds, the change of 

parameter will be by one step corresponding to 1 unit a press. 
 
For  a  rapid  change  the  operator  has  to  keep  one  of  the  two  keys  (

  or 

)  pushed  for  a  time 

longer than 2 seconds. In this case the change of parameter will be by 10 steps correspondent to 
a 10 units a second until the release of the key. 
 
It is advisable never to set the speed increase on a value inferior to 17 otherwise the heating 
will be too slow. 
 

Press 

 key to confirm entry. 

 
The word “Hr.Mn” followed by the last programmed holding time will appear on display. 
 
Four numbers separated by a dot will appear on display. 
The two still numbers on the left side of the dot show the hours, while the flashing numbers on 
the right side of the dot show the minutes. 
 
The first parameter to change are the hours. 
 

The  modification  of  this  parameter  (programming  range  00/20  hours)  is  done  by  using 

  key  (to 

increase value) and 

 (to decrease value) key. 

 
 
 
 
 

- Page 5/9 - 

 

Summary of Contents for PL.06.00

Page 1: ...K Machine POLYMERIZING UNIT Type PL 06 00 PL 12 00 O M E C Snc di R CARNEVALE C Via dell Artigianato 3 5 7 I 20835 Muggi MB ITALY Tel 39 039 793740 Fax 39 039 2780689 E Mail export omec snc com omecsn...

Page 2: ...allation 2 9 3 2 1 Picture No 1 2 9 3 2 2 Picture No 2 3 9 3 3 1 Programming of cycle 4 9 3 4 1 Start up programming 6 9 3 5 1 Working cycle 7 9 3 6 1 Inspections 7 9 3 7 1 Power failures 8 9 3 8 1 Wa...

Page 3: ...and not damaged due to bad carrying b Follow carefully the instructions for installing the machine c The OMEC POLYMERIZING UNIT TYPE PL 06 00 PL 12 00 must be used only by a skilled worker and therefo...

Page 4: ...ic equipment has a good earth and that it is in conformity with the 2006 95 EC Low Voltage 3 1 1 INSTALLATION Verify the apparatus has not stood any evident damage during transportation Place the appa...

Page 5: ...lding time 7 Value increasing key 8 Value decreasing key 3 2 1 PICTURE NO 2 3 3 1 PROGRAMMING OF CYCLE To program a cycle follow correctly and as in the indicated order the instructions below Turn on...

Page 6: ...never to set a value lower then 13 otherwise the heating will be too slow while setting this value always consider the quantity of water inside the tank the more water there is in the tank the slower...

Page 7: ...n sequence If the operator has set FULL as temperature value boiling temperature then the words FULL max speed will appear on display In this case the speed increase is automatically set at FULL max v...

Page 8: ...perator immediate switching on deferred switching on During programming of start up the red leg of key flashes intermittently Immediate switching on Polymerizing unit on OFF press the START STOP key F...

Page 9: ...erature set on the display is reached the time holding value set for the running phase followed by the real temperature of the water inside the tank will be shown on the display just for a few seconds...

Page 10: ...in phases no 1 and no 2 When power returns two cases may present If the power has failed for a short time and the water temperature has not decreased the polymerizing unit will run again all the progr...

Page 11: ...d do not put cable in places where it can be stepped over In case of extended inactivity disconnect the electrical cable Before any transportation always empty the tank and use the original packaging...