![background image](http://html1.mh-extra.com/html/omcan/pe-br-0500/pe-br-0500_instruction-manual_4144632012.webp)
12
Maintenance
Troubleshooting
tightening and corrosion.
Contacts: ON/OFF switch, emergency button, reset button, electronic circuits etc, check the equipment in order
to assure that all components are correctly working and the equipment operation is normal.
Installation: make sure the installation followed all items in the Installation section.
EACH MONTH CHECK:
• Check the electrical installation.
• Measure the voltage at the socket.
• Measure the working current and match it with the nominal current.
• Check the tightening of all electric terminals to avoid bad contacts.
• Check electric motor shaft clearance.
• Check the wiring for overheating, insulation failures and mechanical damages.
EACH THREE MONTH CHECKS:
• Check electrical components such as ON/OFF switch, emergency button, reset button, electronic electric
circuits, overheating, insulation failings, or mechanical damages.
• Check bearings clearances.
• Check retainers, O-rings, V-rings and other seals.
PROBLEM
CAUSES
SOLUTIONS
The machine does not switch on.
Lack of power.
Check if machine is plugged in and
if there is power in the power sup-
ply source.
Problem with the electric circuits
Call Omcan.
Smoke smell or smoke.
Problem in the electric circuit.
Call Omcan.
The machine switches ON but
when the product is placed, the
motor stops or turns too slow.
Problem with the electric motor.
Call Omcan.
Power cord damaged.
Damage during transportation.
Call Omcan.
Abnormal noises
Problem with the bearing.
Call Omcan.
REFERENCE
Item Number Model Number
Description
Manufacturer Model Number
45763
PE-BR-0500
Pizza Dough Opener AMP-500 0.5HP
110V/60HZ
AMP-500