background image

 7  Notes on conformity and disposal 

21

7

Notes on conformity and disposal

7.1

CE Conformity (Europe)

This  product  complies  with  the  requirements  of  Directive  2014/30/EU  concerning

electromagnetic compatibility according to Standard IEC/EN61326-1.

Emission: Class B
Immunity: Applied to industrial and basic environment requirements.

7.2

WEEE declaration (Europe)

In  accordance  with  the  European  directive  on  Waste  of  Electrical  and  Electronic
Equipment,  this  symbol  indicates  that  the  product  must  not  be  disposed  of  as
unsorted municipal  waste but  should  be  collected separately.  Refer to  your  local
authority in the EU for return and/or collection systems available in your country.

7.3

RoHS Conformity (Europe)

This Olympus Soft Imaging Solutions camera conforms with the European Union
directive on the restriction of the use of certain hazardous substances in electrical
and electronic equipment 2011/65/EU.

7.4

FCC conformity (USA)

This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the
following conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
This device has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.
These  limits  are  designed  to  provide  reasonable  protection  against  harmful  inter-
ference in a residential installation. This device generates, uses, and can radiate radio
frequency energy. If not installed and used in accordance with the instructions, it may
cause harmful interference to radio communications. 
However,  there  is  no  guarantee  that  interference  will  not  occur  in  a  particular
installation. 

Summary of Contents for LC30

Page 1: ...English Optical Microscope Accessory To obtain optimum performance of this camera and to ensure the safety study this manual thoroughly before operating the camera and keep it on hand during operation...

Page 2: ...ndirect special incidental or consequential damages arising out of purchase or use of this manual or the information contained herein No part of this document may be reproduced or transmitted in any f...

Page 3: ...oiding personal injuries 8 2 3 Avoiding device damage 9 3 System environment 10 3 1 General remarks 10 3 2 Microscopes and camera adapters 12 3 3 PC 13 3 4 Software 14 4 Installation 15 4 1 Step 1 Ins...

Page 4: ...e cap Camera with protective cap USB 2 0 cable USB 2 0 cable Installation Manual Installation Manual USB 3 0 PCI express card with driver on CD and power supply cable not included in the scope of supp...

Page 5: ...ope by a C mount The ICC profile technology guarantees an optimal color mapping Binning modes The OLYMPUS LC30 has three binning modes In binning mode the camera s CMOS sensor combines neighboring pix...

Page 6: ...tions The maximum permissible range for the ambient temperature during camera operation is 5 C to 40 C The maximum permissible relative humidity during camera operation is 80 condensation free When th...

Page 7: ...re and during the installation 2 1 Explanation of the symbols used Personal injuries Device damage General notes The warning sign and the word WARNING indicate dangerous situations that can lead to se...

Page 8: ...In the case of a fire the material of the camera can give off toxic gases When these are inhaled it can cause irritation of the respiratory passages and damage to them Wear respiratory protection when...

Page 9: ...ensitive and must not come into contact with bare hands or any other objects otherwise the acquisitions will be impaired by fingerprints or scratches Remove dust from the protective glass carefully wi...

Page 10: ...30 can be used in combination with many available micro scopes However its performance in combination with non Olympus microscopes has not been tested Application context Explanation Countermeasure Us...

Page 11: ...y closed Switch on the shading correc tion or decrease illumination intensity and open the AS diaphragm Observing high contrast samples High contrast samples may cause the auto exposure to fail result...

Page 12: ...era adapters with the magnification factor 0 35 or larger are suitable U CMAD3 U TV1x 2 U TV0 5xC 3 U TV0 63xC GX TV0 5xC GX TV0 7xC MVX TV0 63xC MVX TV1xC Upright microscopes BX61 BX51 BX41 CX41 CX31...

Page 13: ...the camera with a laptop Generally speaking it is possible to operate the camera with a laptop If the power supply is not sufficient to operate the camera when an integrated USB interface is used conn...

Page 14: ...dardized software interface between software programs and image acquisition hardware such as digital cameras or scanners You can download the DP2 TWAIN software from this Olympus website https www oly...

Page 15: ...acturer Also pay attention to the safety instructions given below After you have inserted the card make sure to note the following point This step is only necessary when a USB PCI express card is incl...

Page 16: ...programs that run in the background for example antivirus software 2 Browse to the directory that contains the software and double click the setup exe file The installation wizard starts Follow the i...

Page 17: ...cable with the type B plug into the camera socket Make sure that you only use the USB cable that is delivered with your camera The proper functioning of the camera can only be guaranteed when this cab...

Page 18: ...allation only takes a few seconds Please pay attention to the icons displayed in the status bar 5 Wait until the installation of the camera driver has been finished The camera has now been registered...

Page 19: ...an gauze moistened with pure alcohol Cleaning the housing Parts other than the glass components should be cleaned by wiping with a clean cloth Do not use organic solvents to remove major stains Use a...

Page 20: ...tions Install or maintain imaging software Maintain imaging software Provide licenses update installation When the Image source selection dialog box is displayed select the Olympus manufacturer and se...

Page 21: ...h the European Union directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2011 65 EU 7 4 FCC conformity USA This device complies with part 15...

Page 22: ...eorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is...

Page 23: ...7 Notes on conformity and disposal 23 7 6 China RoHS conformity China...

Page 24: ...63 0914 Japan OLYMPUSEUROPASE CO KG Wendenstrasse 14 18 20097 Hamburg Germany OLYMPUSCORPORATIONOFTHEAMERICAS 3500 Corporate Parkway P O Box 610 Center Valley PA 18034 0610 U S A OLYMPUSCORPORATIONOFA...