BX51WI
CONTENTS
3
4-7
8, 9
10-18
IMPORTANT
— Be sure to read this section for safe use of the equipment. —
1 MODULE NOMENCLATURE
2 CONTROLS
3
4 USING THE CONTROLS
TRANSMITTED LIGHT BRIGHTFIELD OBSERVATION PROCEDURE
4-1 Microscope Base, Power Supply Unit (TH4)
................................................................................................
10
4-2 Focusing Block
........................................................................................................................................................................................
11
1
Controlling the Light Intensity (TH4)
2
Using the Filter Turret
4-3 Stage (IX-SVL2)
.............................................................................................................................................................................
12, 13
4-4 Revolving Nosepiece
....................................................................................................................................................................
13
4-5 Observation Tube
.....................................................................................................................................................................
14, 15
1
Adjusting the Interpupillary Distance
2
Adjusting the Diopter
3
Using the Eye Shades
4
Using Eyepiece Micrometer Disks
5
Selecting the Light Path of Trinocular Tube
1
Switching the Objectives (U-SLRE, WI-SRE3)
1
Using the Pre-focusing Lever
2
Using the Fine Adjustment Fast-Feed Knob
3
Using the Frost Switching Lever
4
Adjusting the Coarse Adjustment Knob Rotation Tension
1-2
Correct assembly and adjustments are critical for the microscope to exhibit its full performance. If you are going to
assemble the microscope yourself, please read Chapter 9, “ASSEMBLY” (pages 36 to 42) carefully. For the modules
provided with instruction manuals, also read the assembly procedures in their instruction manuals.
1
Placing the Specimen
2
Moving the Specimen
3
Setting the Grounding
4
Adjusting the X-Axis/Y-Axis Knob Rotation Tension
5
Using the Light Shield Sheet
6
Lowering the Stage Height
4-6 Condenser
..........................................................................................................................................................................................
16, 17
1
Centering the Condenser (Field Iris Diaphragm, Aperture Iris Diaphragm)
2
Oblique Illumination (WI-OBCD)
4-7 Immersion Objectives
..................................................................................................................................................................
18
1
Using Water Immersion Objectives (Water Immersion Cap for XL Objectives XL-CAP)