Changing the Batteries
OPERATING
INSTRUCTIONS
Giu
28
Page
Changing the Batteries
If the battery charge of the sensors is low or practically empty, the following
status messages appear in the display:
Battery capacity low
1.
bAtt Lo
appears in the display. The sensor affected, e.g.
Open Sen
sor01
, is displayed.
2. If you activate the alarm system, 5 successive, short acoustic signals
are issued.
NOTE:
Change the batteries!
Battery charge empty
1.
bAtt off
appears in the display. The sensor affected, e.g.
Open Sen
sor01
, is displayed.
2. If you activate the alarm system, 5 successive, short acoustic signals
are issued.
NOTE:
Change the batteries! A connection between
the sensor and base unit is no longer guaran
teed!
Remote Control
1. Use a precision screwdriver to loosen the screw in the battery com
partment on the underside of the wireless remote control.
2. Remove the cover of the battery compartment.
3. Remove the battery contained.
4. Insert a new CR2430 3 V lithium battery in the battery compartment
(ensure correct polarity).
5. Replace the cover on the battery compartment.
6. Replace and tighten the screw.
Base Unit
The
icon in the display indicates a low battery capacity in the base unit.
Change the batteries!
1. Use a screwdriver to loosen the screw in the battery and connection
socket compartment on the underside of the base unit.
2. Remove the lid from the battery and connection socket compartment.
3. Remove the batteries contained.
4. Insert three new AAA alkaline batteries in the battery compartment
(pay attention to correct polarity).
5. Replace the lid on the battery and connection socket compartment.
6. Replace and tighten the screw.