13
921468007_09_010
3. Installation instructions
3.1.
Quick installation guide
By default the panel has the following settings
Zone 1 : Zone with delay
section
Α
Zone 2 : Zone with delay
section
Β
Ζone 3 : Zone without delay
section
Β
Ζone 4 : Zone without delay
section
Β
Ζone 5 : Zone without delay
section
Α
Ζone 6 : Zone without delay
section
Α
Ζone 7 : Zone without delay
section
Α
Zone 8 : TAMPER zone
Zone 17 (keyboard 1) : Zone with delay section
Α
Entry time : 20 seconds
Exit time : 45 seconds
Siren time : 1 minute
Additional exit time : 20 seconds
We can return to this state if we select
«MASTER OR TECH MENU»
«SYSTEM»
«RESET DE-
FAULTS
» logged in as "TECHNICIAN". With these settings we can do a simple and typical installation
in a residence with an additional perimeter alarm.
Connect to zone1 or to the zone of the keyboard the magnetic contact of the main entrance door. On
zone 2 the radars that monitor the entrance area. On zones 3 and 4 the rest of the radars and on
zones 5 to 7 the magnetic contacts that we require to give an immediate alarm. Finally on zone 8 con-
nect the TAMPER of the external siren. We can either arm section A (perimeter alarm) when we are in
the house or all the system (ABC).
For connection methods see the next section
«CONNECTION»
.
There are 6 pre-made programs that you can select via the technician menu and from the selection
«SYSTEM» and « LOAD PANEL SETTING » (see page 28). These are:
1. Zone 1 : Zone with delay
section
Α
with bell sound
Zone 2 : Zone with delay
section
Α
Zone 3 : Zone without delay
section
Α
Zone 4 : Zone without delay
section
Α
Zone 5 : Silent
section
Α
Zone 6 : Panic
section
Α
Zone 7 : Fire
section
Α
Zone 8 : TAMPER zone
Zone 17 (keyboard 1) : Zone with delay section A
This configuration is suitable for a store. Connect to zone 1 or to the zone of the keyboard the en-
trance magnetic contact. On zone 2 the radars that monitor the entrance area. On zone 3 and zone 4
the rest of the radars and the magnetic contacts that we require to give an immediate alarm. On zone