33
921468007_09_010
If
«ACTIVATED» is selected, the stored telephone number can send commands to the panel only if the
option “Remote access” is activated for this telephone number.
If
«ACTIV BY ALL NUMB.» is selected then any telephone number can send commands to the panel.
For detailed information regarding the GSM card BS-464 (i.e. remote access, SMS command syntax)
refer to the user manual of the BS-464.
Wireless Network
BS-468/A can support up to 32 wireless devices. This feature is
acquired by the presence of BS-479 wireless zones expansion
card. The wireless zones numbering starts at 25 and ends at 56.
By the time BS-479 is scanned successfully (
«SYSTEM»
«SCAN EXTENSIONS» menu), the user can enter «WIRELESS
NETWORK
» menu. The choices of that particular menu are
shown on the right screen.
«VIEW DEVICE»
Information about the connected wireless devices are shown here.
These information are the following:
a) "W/LESS ZONE": The zone number in which the specific de-
vice is assigned (e.g.: 25).
b) "DEV. VERSION": The designated device's program version
(e.g.: V1.27).
c) "BS-470": The device's name that is found in the corresponding
zone (wireless PIR sensor
BS-470, wireless magnetic sensor
BS-471, wireless siren
BS-475, wireless keyboard
BS-477)
d) "ID": This is the unique address each device has.
e) "RSSI:
Χ/4 ": The devices signal strength appears on a scale from 1 to 4.
«ASSIGN ZONE»
Normally, on Network Installation, every device that is recognized, is assigned automatically to the first
free wireless zone number. Through "ASSIGN ZONE" function it is possible to assign a wireless de-
vice to a specific zone of our choice. ATTENTION! If a device already exists in the specific zone, it will
be deleted.
First of all we set the number of the zone we want the device to be assigned
to. The number's range is 25 to 56.
Subsequently, an information screen appears. It explains what keys can be
used for device address. Every device has its own address ID, which can be
found in the devices sticker. That sticker can be found inside the device. Ex-
amples of valid IDs are: 0A00010D, 02001FF9, 07000012, 03000001,
023FDD23.
Digits A - C can be inserted through the wired keyboard by holding them down for 1-2 seconds. Letter
D can be inserted by pressing "ABC". Letter E is inserted by pressing keys "A" + "B" for 1 second and
letter F by pressing and holding "B" + "C". Press "
*
" in order to exit the screen.
___WIRELESS NETWORK____
VIEW DEVICE
ASSIGN ZONE
NETWORK INSTALLATION
DELETE SINGLE ZONE
DELETE ALL ZONES
RF COMM SUPERVISION
WIRELESS TAMPERS
WIRELESS SENSORS
SIGNAL STRENGTH ***
SIREN LED SETTING
RF MASTER INFO
___W/LESS ZONE_25___
DEV. VERSION: V1.27
BS-470
ID: 0200010E
RSSI: 3/4
CHOOSE ZONE