Date
9/7/2018
File
BSR-2114/MAR
Document Number
921211401_09_002
Page
7 από 74
7
1
Introduction section
Thank you for purchasing this product of Olympia Electronics. A European manufacturer. This section contains general
information about the panel and its use. It must be read carefully by all the
users of the panel
so that they can act
accordingly in the event of a fault or alarm condition.
1.1
Description
The
BSR-2104/MAR and BSR-2114/MAR
are used on ships and there are 2 or 4 loop addressable fire detection panels with
expansion capabilities that can upgrade the panel to 8 loops.
The maximum number of loops connected must not exceed 4.
The panels is designed and constructed according to EN54-2 and EN54-4 regulations.
Each loop can accept up-to
150
total points, which can be input units (detectors, call points), output units and line isolators.
The maximum number of fire detectors and manual call points connected to a panel must not exceed 512.
All units that are connected to the loop are referenced and displayed on the LCD panel with the general term
«POINTS»
and
in this term we will be referred to throughout this manual. Each point has a specific address ranging from
1 to 150
in each
loop. Each loop can accept various types of points. We will refer to these points later on in the manual.
The panel has 96 zones and is suitable for larger installations such as malls, shopping centers, hotels and factories.
It offers an extensive selection of settings and options for controlling the equipment and sirens of the installation which can
easily be modified using PC based software.
The panels programming can also be done using a PC.
1.2
Safety
A device is not considered that it is being used correctly if the accompanying documents are not read prior to its use.
This product must be installed, commissioned and maintained by qualified technical personnel according to:
Regulations referring to installing electrical devices in buildings.
Practice rules.
The statutes requirements.
The manufactures instructions.
- The unit operates with 220-240VΑC / 50-60Hz and is rated as a class1 device
(requires a grounding wire for safe operation).
- It must be installed and connected to the power line using it’s own safety fuse with a warning label
«Fire detection system –
Do not isolate»
.
1.3
Indicators and controls
The panel contains a big 320x240 pixel LCD screen which is used to display messages whereas the indications LEDs are used to
show basic warnings (alarm, fault, isolated sections).
The fascia of the panel also contains a 16 button keypad used for controlling the system.
Generally we can see: