16
O
PERATION
M
ODE
In this form you can specify options affecting financial transactions such as VAT rates, and other system options.
Select
Programming Mode -> Configuration Setup -> Operation Mode
.
Navigate to the field you want to personalize and
enter its data (see “Data Entry Mode” for the keys to use). At the end, press
to return to the
Main menu
,or
to return to the previous menu.
NOTE:
Before changing a VAT rate it is recommended that you first print a Z Financial report (see "X and Z
Reports”). For other VAT-related features, see "Printing VAT Information on Customer Receipts".
ECR NUMBER
(Numeric)
Enter a 4-digit Cash Register Identification Number. This number is
printed on the sales receipts, journal records and management reports
issued by the cash register. It is useful to identify the cash register when
more than one cash register is used in the business.
KEY TONE
YES, NO
Key touch-tone audible signal: YES - Enable, NO - Disable.
RECEIPT MODE
RECEIPT,
JOURNAL
RECEIPT = Print receipts, JOURNAL - Save data in journal only, no receipt
printing.
WINDING MOTOR
EJ RPT,
PG/X/Z
Paper winding motor activation: EJ RPT - Motor is activated only when EJ
report is being printed, PG/X/Z - Motor is activated during Programming,
X and Z modes.
Menu Item
Possible Values
Description
VAT Calc
Mode
VAT, ADD-ON
Tax rate to apply to calculations: ADD-ON - Add-on tax rate, VAT - Value
Added Tax.
Tax1 Rate
(Numeric)
Enter a 5-digit number to represent the VAT rate to associate with Tax Rate 1
- THREE digits come after the decimal point.
Tax2 Rate
(Numeric)
The same criteria apply as for entering Tax 1 rate.
Tax3 Rate
(Numeric)
The same criteria apply as for entering Tax 1 rate.
Tax4 Rate
(Numeric)
The same criteria apply as for entering Tax 1 rate.
FC Conv Type
DIVIDE,
MULTIPLY
DIVIDE = Use division for foreign currency conversion calculation, MULTIPLY =
Use multiplication for foreign currency conversion.
%& +/- DEP
CALC
NET, BRUT
/- and %+/- results to departments.
0 Price Reg
YES, NO
Allow zero prices to be registered. YES - Enable, NO - Disable.
Post Tender
YES, NO
Allow other transactions to be entered after tender has been registered. YES
- Enable (default), NO - Disable.
Decimal
0, 1, 2, 3
Set the number of digits after the decimal point. Enter 1 digit for the decimal
position. For example, if 2 is specified, the format used for decimal numbers is
to two decimal places:
x.xx
Rounding
DOWN, UP, OFF
Activate fraction rounding in calculations. Fraction rounding is used to round
figures with decimals up or down to the nearest whole numbers, and is used
for percent tax and percent discount calculations. UP - a fraction of one pence
is rounded up one pence, DOWN - a fraction of one pence is rounded down
one pence, OFF - a fraction over half a pence is rounded up, a fraction equal
to or under half a pence is rounded down.
Menu Item
Possible Values
Description
Summary of Contents for ECR 7900
Page 61: ......
Page 62: ...Code 547404...