Installation environment requirements: low voltage (48V) residential rack battery are designed for household use. 

For installation, it must be installed in a location complying with IP20. If the Installation location does not comply 

with IP20 may cause failure and the product will not be guaranteed for any related accident or damage. 

 
 

3.2

 

Safety Guidelines 

CAUTION

 

Install and use to avoid short-circuit between the anode terminal and a cathode terminal, all electrical connections 

on the low voltage (48V) residential rack battery work must be operated by qualified professional personnel, when 

operated in accordance with the expected design low voltage (48V) residential rack battery will be used as a safe 

and reliable power supply. In the absence of proper operating conditions, damage, misuse and / or abuse case, 

battery box there may be security risks such as overheating or electrolyte smoke potential, users are described in 

this section must comply with the safety precautions and warnings. If any of the following precautions is not fully 

understood or has any problems, please contact the customer service officer for assistance. The safety part may 

not include all the regulations in your area. The use of low voltage (48V) residential rack battery must review 

applicable local laws and regulations and the industry standards of the product. 

Installation personnel shall not wear watches and other metal items to install operations, in order to avoid short 

circuits and personal injuries. 

CAUTION

 

Due to high weight of battery pack, please use original package and do safety protection when second transport. 

Please ensure that the battery box in the process of transportation safety, to avoid damage to the product and 

personnel injury. 

 

4

 

Product Overviews 

 

4.1

 

Produce Introduction 

low voltage (48V) residential rack battery products as the energy storage parts can be used in off-grid & on-grid 

energy storage system. It is recommended not to use this device for other than the purpose described in this 

guidance. The substitute use of this product, random change, and use of components other than sold or 

recommended by Olipower will nullify the product guarantee. 

4.2

 

Identifying The Product 

Battery model 

Specification parameter 

Matched inverter 

LB51100 

51.2V/5.12KWh 

3.2kW 

Detailed data are shown in appendix 1 

 

4.3 Maintenance and Replacement 

 
 
 

Summary of Contents for LB51100

Page 1: ...LB51100 Installation and User Manual 1 Shenzhen Olipower Energy Automation Technology Ltd LB51100 Installation and User Manual Version V1 0...

Page 2: ...Introduction 6 4 2 Identifying The Product 6 4 3 Maintenance and Replacement 6 5 System Installation 7 5 1 Installation notice 7 5 2 Package information and system configuration list 7 5 2 1 Parts li...

Page 3: ...Battery box activate and shutdown 14 6 1 Panel buttons and LEDs meaning 14 6 2 The operation steps of the battery box works alone 14 6 2 1 Start battery box 14 6 2 2 Shut down battery box 14 6 2 3 Lo...

Page 4: ...Shenzhen Olipower Energy Automation Technology Ltd Due to product upgrades or other reasons this document will make appropriate adjustments Unless otherwise agreed this document is intended to be used...

Page 5: ...s Manual This is the Manual for the low voltage 48V residential rack battery products User of this device or installer must refer to the installation guidance to installation and using correctly 2 2 U...

Page 6: ...following precautions is not fully understood or has any problems please contact the customer service officer for assistance The safety part may not include all the regulations in your area The use of...

Page 7: ...ill the regulations and legal enquiry The user has the responsibility and obligation to send it to the designated organization for recycling and disposal 5 System Installation 5 1 Installation notice...

Page 8: ...ed in cartons and the components assort with the battery case When you confirm the good s please read the configuration list carefully to make sure that the battery box and kit are intact 5 2 1 Parts...

Page 9: ...e to side along the wall until the mounting card on the battery box is placed in the proper position of the rack mounting position Information Rack mounted installation is suggested that the external...

Page 10: ...as a parallel battery B B Battery negative The two negative are the same one of which can be used as a parallel battery B Attention B interface RJ45 port corresponding to the CAN bus pin definition R...

Page 11: ...drawing is for reference only please take the material as the standard It is an Australia installation standard requirement AS NZS 5139 that an overcurrent protection and isolation device that operat...

Page 12: ...tch after the need to restart the battery box restart the settings will take effect Single battery box through the LINK communication connection to the inverter when the address DIP switch defined as...

Page 13: ...1 and slave battery box 2 if have slave battery box 2 Step 4 After the battery is completed in parallel it is suggested that you wait a few minutes to connect the inverter later 5 4 3 2 The connection...

Page 14: ...the DIP switch is defined as follows CAUTION Set the DIP switch after the need to restart the battery box restart the settings will take effect Three battery boxes in parallel when the DIP switch is...

Page 15: ...FF Turn on or off button Control battery box on or off RUN Running indicator light green When the battery box is running normally it always bright LOW BAT Low battery indicator yellow When the battery...

Page 16: ...off run LED no longer flashing just on after 90S means the battery into the normal charging mode the battery is not detected charging after 90S the fault red LED will flashing the battery cannot be r...

Page 17: ...attery box and the inverter is normal When the battery box is running fault indicator lights up The battery is too high The battery must be stopped charging immediately Check the communication between...

Page 18: ...t Short circuit cause damage of battery box fuse Check whether the connection is correct and whether there is a short circuit If there is a short circuit please check the cause as soon as possible and...

Page 19: ...weight 46 2kg Installation method Rack mounting Cycle times 80 DOD 25 4000 Charge temperature range 0 55 Discharge temperature range 20 55 communication interface CAN2 0 LINK Modbus RS485 Battery pro...

Page 20: ...LB51100 Installation and User Manual 20 Shenzhen Olipower Energy Automation Technology Ltd Appendix 2 Product size table Product model Outline dimension LB51100...

Reviews: