2 - INSTALLATION
2.1 - TRANSPORTATION, MARKING AND STORAGE
CAUTION
• Transport of equipment containing flammable refrigerants.
Compliance with the transport regulations.
• Disposal of equipment using flammable refrigerants.
Compliance with national regulations.
•
marking of equipment using signs. Compliance with local regulations.
•
Storage of equipment/appliances. The storage of equipment should be in accordance with the manufac
-
turer’s instructions.
•
Storage of packed (unsold) equipment. Storage package protection should be constructed such that me
-
chanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will be
determined by local regulations.
2.2 - INSTALLATION AND ADJUSTMENT
Before using the portable air conditioner, keep it upright for at least two hours.
The portable air conditioner can be easily moved in the room. In the moving process, ensure that the unit is
in an upright position and placed on a flat surface.
Do not install and use the air conditioning in the bathroom or other humid en-
vironments.
Install the exhaust pipe assembly (fig.2):
a.
Take out the outer connector assembly and
the exhaust pipe assembly, and remove
the plastic bags;
b.
Insert the exhaust pipe assembly (the end
of the exhaust joint) into the back panel
vent slot (push to the left) and complete
the assembly.