10C - 12C - 18C
3
1,5 mm
2
20 A
24C
3
2,5 mm
2
32 A
EN - 18
ENGLISH
e
. Block the cable (28) using the cable tie (29).
Key (figure 29a)
21
Panel
22
Terminal board lid
23
Indoor unit terminal board
24
Connection cable to the outdoor unit
25
Cable tie
2.7.3 - Outdoor unit electric connection (Figure 29b)
a
. Loosen the screw (27) and remove the electric control board protection (26) of the outdoor unit.
b
. Connect the cables to the terminal board (30) following the identification numbers on the terminal board
of the indoor and outdoor units.
c
. To prevent the entry of water, form a loop with the connection cable, as shown in the installation diagram
of the indoor and outdoor units.
d
. Insulate unused wires (conductors) using electrician’s tape. Make sure they do not touch electric or metal
parts.
e
. Block the cable (29) using the cable tie (31).
Key (figure 29)
26
Protection
27
Screw
28
Connection cable to the indoor unit
29
Cable tie
30
Outdoor unit terminal board
The earth cable must be fixed to the dedicated terminal, present in the electric
connections compartment of the indoor unit.
2.7.4 - Electric connection
Before connecting the air conditioner, make sure that:
a. The power supply voltage and frequency values respect that specified on the appliance data
plate.
b. The power supply line has an effective earth connection and it is correctly dimensioned for
maximum absorption of the climate control unit.
c
. To select the minimum section of the power supply cable, refer to the table below.
Outdoor Unit
Model
Number of power supply
cable poles
Minimum section of the electric power
supply cable
Recommended
fuse
A suitable omnipolar disconnection device must be envisioned on the appliance
mains electric power supply, in compliance with the national installation rules.
It must be checked that the electric power supply has an effective earth and suitable
protections against overloads and/or short circuits.
The use of a ceramic fuse of the characteristics shown in the table is advised (or
other devices with the same functions).
The connection to the mains power supply must be made by the installation techni-
cian (excluding mobile appliances, for which fixed installation by qualified personnel
is not required) in compliance with the regulations in force.
Summary of Contents for ARYAL S1 E 10 C
Page 2: ......
Page 9: ...10 12 11 13 90 14 16 15 D E F C B A 6 5 5 A A B 2 2 1 1 3 17...
Page 10: ...A B min 1500mm 21 23 22 24 26 25 20 OK b a 18 20 19 20 27...
Page 11: ...8m 30 31 A B E G C D F 33 W 2 N 1 L S 25 24 22 21 23 29a 26 27 28 29 30 28 29b 32...
Page 12: ...38 39 37 36 click 40 41 4 2 1 5 10 6 4 11 3 8 7 9 34 35...
Page 13: ...44 46 45 47 a b 42 43...
Page 226: ...EL 2 0 0 1 0 2 0 2 1...
Page 229: ...ARYAL S1 E INVERTER 10 12 18 24 C EL 5 0 4 12 0 5 X OLIMPIA SPLENDID 0 6 1 1 1...
Page 233: ...ARYAL S1 E INVERTER 10 12 18 24 C EL 9 h i l...
Page 234: ...X1 A EL 10 2 3 15 2 4 a b 120 mm 150 mm 1 c 2 3 d e 2000 mm f g 3 max 25 m A max 10 m...
Page 252: ...EL 28 4 2 1 4 3 1 a 3 b 4 10 2 COOL 3 4...
Page 315: ......
Page 316: ...265762A...