background image

Modular Wireless I/O System – User Guide  

 

1.

 

PREFACE/SAFETY 

 

Thank you for choosing the WIO® Modular Wireless I/O System by OleumTech®.  
 
This system is a point-to-point, bi-directional wireless I/O mirroring solution that is ideal for replacing hardwire and 
conduit or for implementing it into new or existing infrastructures.  The WIO System requires no software or 
programming and is extremely easy to install and use. It’s the easiest way from point A to point B, and back. 
 
This document is designed to guide you through setting up the system by familiarizing you with the hardware, 
installation, wiring, and overall system management. This guide also provides how to use the WIO System’s Advanced 
User Interface.  
 
You can also utilize the online video training program available on at http://wio.oleumtech.com as a supplemental 
learning tool. 
 
If you have any questions about this product, you may call or email: 
 

ProSoft Technology Support Services 
1.661.716.5100

[email protected]om

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for Wio BM-0868-RM1

Page 1: ...Modular Wireless I O System User Guide Version 80 7046 001_M Model Numbers RADIO KITS BM 0868 RM1 BM 0900 RM1 BM 0915 RM1 BM 2400 RM1 I O MODULES BM D100 144 BM A420 122 BM A010 122...

Page 2: ...ST PRACTICE 13 7 SIGNAL CHAIN DIAGRAM 14 8 RADIO MODULE WIRING DIAGRAMS 15 9 DIGITAL I O MODULE WIRING DIAGRAMS 17 10 ANALOG 4 20 mA I O MODULE WIRING DIAGRAMS 21 11 ANALOG 0 10 V I O MODULE WIRING DI...

Page 3: ...asy to install and use It s the easiest way from point A to point B and back This document is designed to guide you through setting up the system by familiarizing you with the hardware installation wi...

Page 4: ...wn to be non hazardous AVERTISSEMENT Assurez vous que l installation du syst me r pond aux exigences du code lectrique national et national en vigueur AVERTISSEMENT L installation du syst me ne doit t...

Page 5: ...are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and...

Page 6: ...r can defines how outputs are failed over when RF or I O communication is ever lost FailSafe output modes Digital On off last known value default Analog Any value on scale Advanced UI required last kn...

Page 7: ...input and output status set analog fail safe output values locally force outputs for diagnostic testing and more Just Add I O Modules Constructing a Modular Wireless I O System begins with a WIO Radio...

Page 8: ...g Module BM A010 122 a 2 Pack BM A010 122D 1 Pack BM A010 122S 5 DataRail attaches onto 35 mm x 7 5 mm DIN rail a Part 61 7000 001 included with Radio Kit 6 fits Radio Module 5 I O Modules b Optional...

Page 9: ...arious types of antennas including bulkhead omni and yagi Please use the appropriate type for your application 6 Connecting a lightning arrestor is highly recommended 7 Install antenna performing a RF...

Page 10: ...io et d E S doit tre enti rement assembl avant d alimenter le module radio pour que le syst me d marre et fonctionne correctement Si vous ne le faites pas la liaison RF et la liaison E S peuvent choue...

Page 11: ...O Module to set device ID s Each pair of Modules must be set to its own ID for the system to function properly Chaque paire de modules doit tre d finie sur son propre ID pour que le syst me fonctionn...

Page 12: ...ireless I O System User Guide 11 6 Protect any unused DataRail slots with Cover Snap off extra pieces and store for future use 7 Terminate I O and supply power as required Use solid or stranded wire A...

Page 13: ...retirer tout composant du syst me DataRail ou WIO 1 End Terminal Bracket can be removed from din rail by inserting the tip of a flathead screwdriver into the removal slot Control the direction with th...

Page 14: ...na cables with the WIO System for best performance 4 After entire system is installed verify RF LED on Radio Module is green which serves as indication for good RF traffic 5 Advanced Run RSSI test Con...

Page 15: ...Modular Wireless I O System User Guide 14 7 SIGNAL CHAIN DIAGRAM...

Page 16: ...onnect RF Link Alarm output to report when there is an RF link failure This Input allows connection of a dry contact switch for manually overriding system into FailSafe state for all outputs Radio Mod...

Page 17: ...Modular Wireless I O System User Guide 16 B Isolation vs Non Isolation...

Page 18: ...nput sensor is powered from the same source as Radio Module be sure to establish a common ground otherwise sensor will not work properly Le module d E S num rique ne partage pas une masse commune avec...

Page 19: ...Modular Wireless I O System User Guide 18 B Digital Input Wiring...

Page 20: ...Modular Wireless I O System User Guide 19 C Digital Output Wiring...

Page 21: ...turn on when dry contact switch is closed or Digital Input Voltage is less than 1 1 V For active high digital output device LEDs will have a reverse effect When signal is greater than 2 4 V LEDs will...

Page 22: ...4 20 mA I O Module does not share a common ground with Radio Module All inputs and outputs on I O Modules provide field isolation Le module d E S 4 20 mA ne partage pas une masse commune avec le modul...

Page 23: ...Modular Wireless I O System User Guide 22 B 4 20 mA Input Wiring...

Page 24: ...Modular Wireless I O System User Guide 23 C 4 20 mA Output Wiring...

Page 25: ...Solid Stranded AWG 28 12 Wire Gauge 0 10 V I O Module does not share a common ground with Radio Module All inputs and outputs on I O Modules provide field isolation Le module d E S 0 10 V ne partage...

Page 26: ...may negatively impact RF signal quality 3 I O LED Right a Green Modules detected I O ok b Red I O link failure i Visual indication of I O link failure ii I O Link Alarm Output P1 NPN is triggered to...

Page 27: ...r pleinement de toutes les fonctionnalit s disponibles sur le syst me WIO A Download and Install Software a Click here to download the latest version of the software or go to the web site http wio ole...

Page 28: ...F When PC is not connected to a Radio Module all gauges and controls are disabled b ON When PC is connected to a Radio Module powered on all gauges and controls will be enabled OFF DISCONNECTED ON CON...

Page 29: ...apply in order for any changes to become effective on the local device 5 RF Link Alarm Output and Operating in FailSafe mode is triggered by this RF timeout interval a 10 second default RF timeout adj...

Page 30: ...a The RF Link Fail Output NPN on Radio Module also triggered when failure occurs 2 I O Link Failure Indicator a The I O Link Fail Output NPN on Radio Module also triggered when failure occurs 3 Red B...

Page 31: ...c Closing the User Interface or unplugging the mini USB cable will automatically deactivate any forced output s 5 Orange LED displayed when output is forced on 6 Displays FailSafe mode that has been...

Page 32: ...is indicated in blue on dial and numeric display including last known value c Apply button must click apply for changes to take effect 6 Force Output Button a Press F button to manually force a specif...

Page 33: ...value Set value is indicated in blue on dial and numeric display c Apply button must click apply for changes to take effect 6 Force Output Button a Press F button to manually force a specific output...

Page 34: ...lculator http goo gl t67r3k DIN Rail Mounting Compatibility 35 mm x 7 5 mm DIN Rail DataRail 6 1 156 mm Supports Up to Five 5 I O Modules 2x Included with Radio Kit Other Lengths Also Available I O Mo...

Page 35: ...U SAFETY COMPLIANCE RADIO BM 0900 RM1 Class I Division 2 Groups A B C D T3 Ex nA IIC T3 Gc Class I Zone 2 AEx nA IIC T3 Gc Tamb 40 C to 80 C BM 2400 RM1 BM 0915 RM1 and BM 0868 RM1 ATEX Sira 15ATEX413...

Page 36: ...read Spectrum 868 MHz LBT AFA 900 MHz FHSS 2 4 GHz DSSS RF Security 128 bit AES Encryption Controlled Local Shutdown ESD Yes via Provided Dry Contact Input RF Link Alarm Digital Output Adjustable 2 to...

Page 37: ...7 5 x 99 x 114 mm Packaging Weight Single 0 5 lbs 227 g Double 0 8 lbs 363 g Net Weight Single 0 3 lbs 136 g E 4 20 mA I O MODULE Number of Inputs 2 24 bit Resolution Number of Outputs 2 16 bit Resolu...

Page 38: ...ohm Power Consumption Typical 40 mA Max 45 mA 12 Vdc Packaging Dimensions WxHxD 4 8 x 5 1 x 2 8 in 123 x 129 x 72 mm Net Dimensions 0 7 x 3 9 x 4 5 in 17 5 x 99 x 114 mm Packaging Weight Single 0 5 lb...

Page 39: ...a Yes both US and International versions are available 7 Is WIO offered in 2 4 GHz license free ISM band a Yes both US and International versions are available 8 At max RF power of 250 mW what is the...

Page 40: ...ilable via mini USB port b For security reasons once two Radio modules are paired together from factory they cannot be unpaired 19 Is the WIO System compatible with WirelessHART protocol a No the WIO...

Page 41: ...that the goods or systems or any part thereof are i misused abused or otherwise damaged ii repaired altered or modified without OleumTech s consent iii not installed maintained and operated in strict...

Page 42: ...s must be fully assembled before supplying power to the Radio Module for the system to boot and operate properly Failure to do so may cause RF link and I O link to fail Rev J Revised document templat...

Page 43: ...ess for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers OleumTech shall not be held liable to anyone for any indirect s...