Page 39
DH3 WIRELESS GATEWAY
USER GUIDE
20.
UPDATE DH3 FUNCTION IN BreeZ®
(PROGRAM/CONFIGURE DH3)
DH3 can be programmed or “updated” using a Mini USB or Ethernet
connection. In order to keep intruders out, accessing DH3 requires user
authentication. The connection over Ethernet is secure using SSL/TLS
encryption method. Via Mini USB and Ethernet, simultaneous Modbus
Master and Slave function is supported. E.g. In BreeZ®, registers can be
polled while viewing Debug information at the same time.
2 Methods for BreeZ® to DH3 Connectivity:
Mini USB port:
(May need to update usb8023.sys driver, if there are
connection issues, see sec 46 item 1)
1.
Update DH3 (program) - BreeZ®
2.
Connect to DH3 (view device settings) - BreeZ®
3.
View Debug information (device activities) - BreeZ®
4.
Simultaneous Master/Slave function (TCP)
Ethernet port: Default Static IP Address is 10.0.0.10
1.
Update DH3 (program) - BreeZ®
2.
Connect to DH3 (view device settings) - BreeZ®
3.
View Debug information (device activities) - BreeZ®
4.
Web Server – Web Browser (DHCP/Static IP address)
5.
Simultaneous Master/Slave function (TCP)
Use USB 2.0 to Fast Ethernet Adaptor when Ethernet port not
available (Do not use USB 2.0 to Gigabit Ethernet Adaptor).
Admin level access has the ability to change passwords and have
read/write access to DH3.
Default Admin Password:
admin/admin
DO NOT LOSE PASSWORDS!
NE PERDEZ PAS PASSWORDS !
User level access has read/write access to DH3.
Default User Password:
user/user
1.
Connect 9-30 VDC power to DH3
2.
USB/Ethernet Connection
a.
Connect USB end of the Cable to PC
b.