Optional reflectors
Width
24"
61 cm
Depth:
18"
46 cm
Intensity
Low
Medium
High
AP 30-5000
1kW
2.5kW
5kW
AP 30-8000
2kW
4kW
8kW
Cooling
A self-contained air conditioning system is integrated into the rear of the
AP 30-5000 / AP 30-8000.
Exhaust
Two exhaust ducts, diameter 8 in.(203 mm)
To minimize the impact on the working environment, the exhaust must
be vented to the outside, a heat exchanger or up through a dropped ceiling.
A/C Filter
Rear
Front
36"
Power
36"
36"
Top View
Room Air Supply
The exposure lamp cooling air is drawn from the exposure room. The
ventilation system must be sized to maintain positive pressure in the
exposure room for cleanliness and to avoid drawing chemical fumes into
the printer.
Water Drain
A water drain or sump pump is necessary for the air conditioner
condensation.