7-6
94MS36 Rev. F2 S/W Ver 2.06
Glass Photo Tool (Optional)
•
If the unit is equipped with the Glass Photo Tool Option you will have a
third vacuum pump installed in the bottom of the unit..
•
See section Vacuum Pumps and section Tubing/Fitting Replacement for
vacuum problems.
•
The vacuum pump used for the glass tool is independent of the integrator
and is used to hold the art work to the glass tool. The operation of the
pump is controlled by the buttons on the left front on the nose of the unit.
•
The button labeled *xpump must be pressed to turn on the vacuum pump.
•
Once the pump has been turned on then the button for the upper tool or
lower tool can be pressed to activate the respective solenoid in order to
hold the art work to the glass tool.
•
Several different glass tools are available according to customer needs
so each tool itself is going to be different, however the electrical wiring
and operation is the same.
•
Wiring Diagram for Glass Photo Tool Option
J22
PUMP
UPPER
TOOL
LOWER
TOOL
P70
P71
P72
(BLACK, 18 GA)
(BROWN, 18 GA)
(BLUE, 18 GA)
(GRN/YEL, 18 GA)
(GRN/YEL)
(18 GA)
16D2741A00
(RED, 18 GA)
(RED, 22 GA)
(BLACK, 22 GA)
(ORANGE, 22 GA)
VAC3
(WHITE, 22 GA)
(BLACK, 22 GA)
(RED, 22 GA)
(WHITE, 22 GA)
(ORANGE, 22 GA)
(BLACK, 22 GA)
(BLACK, 22 GA)
(BLACK, 22 GA)
(BLACK, 22 GA)
16D3211A00
16D3212A00
(RED, 22 GA)
(BLACK, 22 GA)
(WHITE, 22 GA)
(ORANGE, 22 GA)
(GREEN, 22 GA)
(BLACK, 22 GA)
P69
(BLACK, 22 GA)
(BLACK, 22 GA)
(ORANGE)
( 22 GA)
(WHITE)
( 22 GA)
(GREEN)
( 22 GA)
(RED, 22 GA)
(RED, 22 GA)
NEUTRAL
240VAC
RELAY
DC COM
12 VDC
GTOOL
GTOOL PUMP
(240V)
SW 15
SW 16
SW 17
4
L1
(a)
3
4
3
4
3
L2
L3
(b)
(b)
(a)
(b)
(a)
SOL4
SOL5
5
6
4
3
2
1
1
2
3
4
5
6
7
8
UPPER
VALVE
(12VDC)
LOWER
VALVE
(12VDC)
1
2
1
2
1
2
3