2-4
94MS36 Rev. F2 S/W Ver 2.06
Operator Control Panel
P
The AP 30 heavy duty exposure system has a power key on the integrator.
•
Press the
P
key to turn on the unit.
•
Press the
P
key again after use, and the system will run through a 2
minute cool down cycle and then turn off all blowers.
S
STOP Button
•
Press the
S
button once. Frame movement will stop.
•
Press the
S
button once more, the frame will return, at slow speed, to
the original position and vacuum will turn off.
•
Press the
S
button twice to cancel an exposure.
•
Holding the
S
button down then pressing the
G
button starts a blank
cycle - no vacuum or exposure.
G
GO Button
•
Press the
G
button once to initiate vacuum drawdown on the exposure
frame.
•
Press the
G
button a second time to move the frame into the unit and
start an exposure.
•
If frame switch
[FrCl]
and auto vacuum
[AUAC]
are turned on, press the
G
button once to move the frame into the unit and start an exposure.
•
If frame switch
[FrCl]
and auto vac
[AUAC]
are turned on, press the
G
button once without opening the upper or lower frame will start a blank
frame cycle - no vacuum or exposure.
Note:
If a vacuum delay
[dUAC]
is used, the exposure will not begin
until the vacuum delay time has counted down.
Table Showing the 12 Calibration Positions
4th
3rd
2nd
1st
8th
7th
6th
5th
12th
11th
10th
9th
[Lb]
[Lt]
[Ub]
[Ut]
Lower Frame, Bottom Surface
Lower Frame, Top Surface
Upper Frame, Bottom Surface
Upper Frame, Top Surface
Calibration Procedures
Note:
The AP30 high resolution printer has been calibrated at the factory.
Note:
The following calibration procedures can be applied to all three
light intensities, if starting calibration from scratch. To adjust
existing calibration set the integrator to 500 mj and make the
exposure. Increase or decrease the calibration number the same
percentage the 500 mj is off.