![Okuma ICB1-S Maintenance Manual Download Page 13](http://html1.mh-extra.com/html/okuma/icb1-s/icb1-s_maintenance-manual_3666760013.webp)
4742-E P-8
SECTION 1 INVERTER UNIT (MIV UNIT)
2-4.
MIV Unit Selection Tables by Motor Types
2-4-1. BL Motors
Eeospcsa1008
For BL motor control, 1-axis and 2-axis specification MIV units are provided.
The standard combinations of BL motor types and MIV unit types are shown below.
(Note that the relationship may be changed according to the machine specification.)
(1) Max. torque/Rated torque = 300%
* MIV0304-1 unit does not have a 2-axis control type. Use MIV0404 unit.
Motor Type
Rated Motor Output
{kW (hp)}
MIV Unit
1-axis spec.
2-axis spec.*
BL-MC24J-30
0.75 (1)
MIV01-1
MIV0101-1 (L/M)
MIV0102-1 (L)
MIV0103-1 (L)
MIV0104-1 (L)
BL-MC25J-30
0.75 (1)
BL-MC50J-20
1 (1.33)
BL-MC100J-12
1.2 (1.6)
BL-MC50J-30
1.5 (2)
BL-MC75J-20
1.5 (2)
BL-MC150J-12
1.8 (2.4)
BL-MC95J-20
2 (2.67)
MIV02-1
MIV0102-1 (M)
MIV0202-1 (L/M)
MIV0203-1 (L)
MIV0204-1 (L)
BL-MC100J-20
2 (2.67)
BL-MC75J-30
2.2 (2.93)
BL-MC200J-12
2.4 (3.2)
BL-MC140J-20
2.8 (3.73)
BL-MC95J-30
3 (4)
MIV03-1
MIV0103-1 (M)
MIV0203-1 (M)
MIV0303-1 (L/M)
* MIV0404-1 (L)
BL-MC100J-30
3 (4)
BL-MC150J-20
3 (4)
BL-MC300J-12
3.6 (4.8)
MIV04-1
MIV0104-1 (M)
MIV0204-1 (M)
MIV0404-1 (L/M)
BL-MC190J-20
4 (5.33)
BL-MC200J-20
4 (5.33)
BL-MC140J-30
4.2 (5.6)
MIV05-1
BL-MC400J-12
4.8 (6.4)
BL-MC300J-20
6 (8)
MIV06DB-1
BL-MC400J-15
6 (8)
BL-MP400J-20
6.7 (8.93)
MIV08DB-1
BL-MH700J-10
7 (9.33)
BL-MC500J-15
7.5 (10)
BL-MP300J-30
5.1 (6.8)
MIV15-1
BL-MP400J-25
6.2 (8.27)
BL-MP500J-20
7.1 (9.47)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com