1) Refrigerant currently recovered from the vehicle
2) Refrigerant pressure in the vehicle
In order to assure a perfect recovery and oil separation, the unit modulates the gas flow in relation to its
pressure. The ecovery cycles may therefore be alternated by intervals. The operation is followed by a
waiting period to check for any gas residuals in the system. The length of this test tim can be set in the
OPTIONS
menu. The unit then drains any oil recovered during the recovery phase.
3) Time left to the end of the test time
4) Oil drain duration
3.4.2.3 Vacuum
By selecting VACUUM it will be possible to set the duration of the vacuum.
Press ENTER
Decrease/increase the
vacuum length by means
of the buttons UP and
DOWN
Press
EXIT
to return to START If , on the oposite, you press ENTER again the unit checks if there is no
pressure in the lines and, starts the vaccum The vacuum cycle is automatically followed by a leak test cycle
under vacuum according to the set parameters )
Note: the unit gives out acoustic signals until a good vacuum level is reached. In case of a
remarkable leakage, when this level is never reached, the unit continues the signal and therefore
warns the operator.
3.4.2.4 Leak test under vacuum
By selecting LEAK TEST , it will be possible to set the duration of the leak test under vacuum.
Press ENTER
Decrease/increase the
vacuum test length by
means of the buttons UP
and DOWN
Press
EXIT
to return to START By pressing the button ENTER again, the unit would carry out a capacity test
under vacuum according to the parameters set before.
(select this option only if the vacuum in the system has already been carried out)
3.4.2.5 Oil injection into A/C system
By selecting icon OIL INJECTION, you access the oil injection selection menu
Ecos-150 sw 1.x.x - ver. 1.0
Page 12/20