Page: 12
Service Manual for OF5800
Chapter 2 Machine Operations
The power supply unit receives the input line voltage and converts it to output voltages of +5 VDC, +24
VDC,+12 VDC, and -12 VDC.
If an over current condition is sensed in the secondary circuit, power is interrupted.
The power supply unit has three output connectors. The following table shows the connector outputs: CN1
to the Printer Mechanical Control PCB, CN2 to the Fuser Heater, and CN3 to the Main Control PCB.
CN1 Printer Mechanical Control PCB
Pin No.
1
2
3
4
5
Output
+24V
GND
GND
+5V
H.L
CN2 Fuser
Pin No.
1
2
3
Output
N
N.C
L
CN3 Main
Control
PCB
Pin No.
1
2
3
4
5
6
7
8
Output
+24V
+24V
GND
GND
+12V
-12V
+5V
+5V
Image and programmed data is backed-up in the event of a power failure.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)