MSM9225B User’s Manual
Chapter 2 Register Descriptions
2 – 32
Notes on how to set the Group Message function
When setting the Group Message (GM) function in the message box that selects the extended format as a
frame format, specify the message box numbers consecutively, beginning with the message box with the
largest message box number.
Figure 2-31 (a) shows an example of how to set the GM function in two message boxes when 16
message boxes are used. First, set NMES0 to NMES3 of the message box count setting register
(NMES: 1Ehex) to “1111”. Next procedure is to set the GM function in the message boxes F and E.
To do so, set GMR03 to GMR00 of the GMR0 (group message register) and GMR13 to GMR10 of the
GMR1 to “1111” (FH) (message box number) and “1110” (EH) (message box number), respectively.
In this case, it is also possible to set GMR03 to GMR00 to “E” (message box number) and GMR13 to
GMR10 to “F” (message box number).
Figure 2-31 (b) shows an example of how to set the GM function when 6 message boxes are used.
Message box
number
Message box
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
GM1
←
Set the GM function (GMR1)
Specify the number
of message boxes
to be used using
NMES0 to NMES3
of NMES (1 Ehex).
NMES3 to NMES0:
“1111”
F
GM0
←
Set the GM function (GMR0)
(a) When 16 message boxes are used
Message box
number
Message box
Message box
number
Message box
0
0
1
1
2
2
3
3
4
4
GM0 or GM1
NMES3 - NMES0:
“0101”
5
GM0 or GM1
5
GM1 or GM0
(b) When 6 message boxes are used
Figure 2-31 Example of how to set the GM function
To set the GM function, specify the
message box numbers consecutively,
beginning with the largest message box
number.
GMR0 (3Ehex)
EGM0: “1”, GMR03 to GMR00: “1111”
GMR1 (3Fhex)
EGM1: “1”, GMR13 to GMR10: “1110”
Summary of Contents for MSM9225B
Page 7: ...Chapter 1 Overview...
Page 13: ...Chapter 2 Register Descriptions...
Page 53: ...Chapter 3 Operational Description...
Page 62: ...Chapter 4 Microcontroller Interface...
Page 71: ...Chapter 5 Electrical Characteristics...
Page 81: ...Appendixes...