42114101 Rev.1
104 /
6.5
Troubleshooting flow chart
1
Power is not supplied.
Is the AC cable connected correctly?
Yes
No
Connect the AC cable correctly.
Is fuse F1 on the transformer assy/or F1 on the Power Supply Board blown?
No
Yes
Replace fuse (with same type and rating).
Remedied?
No
Yes
End
Does DC + 50V out?
No
Yes
Remove Print Head. (Turn power off, then on.)
Remedied?
No
Yes
End
Replace carriage cable or ribbon feed mechanism.
Remedied?
No
Yes
End
Replace Control Board
Remove CN3 on Power Supply Board
Measure for any short circuits b 5V, + 50V, + 12V, - 8V, 0V in CN2 of Control
Board.
Any short circuit?
No
Yes