44952001TH Rev.2
5-7
Oki Data CONFIDENTIAL
5. MAINTENANCE MENUS
Item1
Item2
Item3
Item4
Item5
Value
Default
value
ODA
Default
value
OEL
Default
value
JP
Notes
Password
Scanner
Maintenance
Mechanical
Test
FBS Test
Speed
Color 300x300dpi
Color 300x600dpi
Color 600x600dpi
Mono
Conduct mechanical testing (without reading an image).
ADF : Test moving original document (stops when set document has been moved)
May choose from single- or double-sided feeding.
FBS : CIS moving test (stops after designated number of operations)
Use fastest read speed (40 cpm).
Display "Testing" during execution?
→
On the panel, indicate current number of executions using the message "Test no. xxx
underway."
TImes
0~65535
Execute
--results--
Test no. xxx underway
Sensor
Test
Examples of this display are
shown below:
①
MEDIA H/L
②
SCAN H/L
③
REVERSE H/L
④
ADF CVR H/L
⑤
FB H/L
Display sensor status (H/L) in real time. Change the content of the display as needed
when the sensor status displayed changes.
①
Set-document detection sensor (MEDIA)
②
Scanning sensor (SCAN)
③
Reverse sensor (REVERSE)
④
ADF cover-open senor (ADF CVR)
⑤
FB home-position sensor (FB HP)
ADF Motor
Test
Forward
Forward Continuous
Reverse
Reverse Continuous
Test the ADF motor
①
After a short press of the button, rotate in the CW direction for 10 seconds and then stop.
②
After a long press of the button, rotate in the CW direction continuously. Stop when the
Stop button is pressed.
③
After a short press of the button, rotate in the CCW direction for 10 seconds and then
stop.
④
After a long press of the button, rotate in the CCW direction continuously. Stop when the
Stop button is pressed.
Deemed successful at all times. No need to display results.
Display "Testing" during execution?
→
Display a message on the panel showing that testing is underway.
Solenoid
Test
Once
Continuous
After a short press of the button, intake for 2 seconds and then stop.
After a long press of the button, intake for 2 seconds and stop for 3 seconds repeat.
Stop when the Stop button is pressed.
Deemed successful at all times. No need to display results.
Display "Testing" during execution?
→
Display a message on the panel showing that testing is underway.