2
2-25
Using AutoCal and ColorCal
12.
Place the Kodak Gray Scale strip, Kodak Colour Control Patches strip, and scanner
measurement page in the correct positions on the copier glass for scanner calibration.
Place the Gray Scale strip face down on the platen glass so that it will be centered along
the top edge of the scanner measurement page. Then place the Colour Scale strip face
down on the platen glass so it is centered below the Gray Scale strip. Finally, place the
scanner measurement page (second one printed) face down over the strips.
13.
To perform the scanner calibration, click Continue in the ColorCal dialog box
that appears.
After the scanner has been calibrated, another dialog box appears, prompting you to
calibrate the Fiery.
14.
Click Measure in the AutoCal or ColorCal Get Measurements pane.
15.
Follow the directions in the dialog box for placing the Gray Scale strip and the
measurement page on the printer glass. Click Continue.
16.
Click Continue in the Calibrator Information dialog box (on your Windows or Mac OS
computer).
AutoCal
ColorCal