background image

 

 20

 The trademark is a registered trademark belonging to OJ Electronics A/S 

· 

© 2014 OJ Electronics A/S

Fig. 1 - Dimensions, front view

Fig. 3 - Configuration, complete with 2 x Fan IO 

Fig. 4 - External communications ports 

Fig. 2 - Dimensions, side view 

Fig. 5 - Internal communication ports

Fig. 6 - Connections in RJ12 port for internal communication 

OJ Electronics A/S

Stenager 13B · DK-6400 Sønderborg

Tel. +45 73 12 13 14 · Fax +45 73 12 13 13

[email protected] · www.ojelectronics.com

   BR970A04

a

   BR970A01

b

   BR969A10

a

   BR970A

05a

   BR970A06

a

   BR923A

07a

Summary of Contents for Air2 Master

Page 1: ...communication CONFIGURATION At the factory The system designer configures the ventilation system at the factory via the user friendly OJ Air2 Master Web interface and saves the settings in a data file...

Page 2: ...1 should be connected to the Din 1 input terminals 3 4 Digital input 2 should be connected to the Din 2 input terminals 4 5 Note terminal 4 is shared by Din 1 and Din 2 Digital input 3 should be conn...

Page 3: ...supply for OJ Air2 Master No communication between PC and OJ Air2 Master which are connected via router The IP address is allocated from the router Wrong IP address Read off the OJ Air2 Master IP addr...

Page 4: ...e K hlung L fterregelung Konstanter Luftstrom Konstanter Druck Zuluftdruck m Slave Abluftdruck m Slave Konstantes CO2 Niedrige Drehzahl hohe Drehzahl Umluft Konstanter Betrieb Automatikbetrieb Brand B...

Page 5: ...gitalen Ausg nge 3 7 d rfen max an 30 V angeschlossen werden Digitalausgang 3 ist an Ausgang Dou 3 an den Klemmen 28 und 29 anzuschlie en Digitalausgang 4 ist an Ausgang Dou 4 an den Klemmen 30 und 31...

Page 6: ...ollieren Falsche Konfiguration der digitalen Eing nge Konfiguration im Men OJ Module Konfigurieren kontrollieren und ggf mittels Ihrem Web Browser korrigieren Die Spannungsversorgung zum OJ Air2 Maste...

Page 7: ...lation chauffage de nuit Refroidissement de nuit d t Refroidissement forc Contr le de ventilateur D bit constant Pression constante Pression d entr e en esclave Pression de sortie en esclave CO2 const...

Page 8: ...ants Sorties num riques L OJ Air2 Master est muni de sept relais num riques de sortie avec contacts secs Les sorties num riques 1 2 peuvent tre raccord es max 230 V CA CC AC1 La sortie num rique 1 doi...

Page 9: ...se adresse IP Notez l adresse IP de l OJ Air2 Master l aide de l OJ Air2 HTERM et entrez la dans le champ d adresse de votre navigateur Mauvaise adresse IP dans le navigateur Entrez la bonne adresse I...

Page 10: ...rkompensering tercirkulation nattuppv rmning Sommarnattskylning Kylforcering Fl ktstyrning Konstant fl de Konstant tryck Inbl sningstryck med slav Utsugningstryck med slav Konstant CO2 L g hastighet h...

Page 11: ...utg ng 7 ska anslutas till utg ngen Dou 7 p plintarna 36 och 37 Elanslutningen visas i fig 7 Analoga utg ngar OJ Air2 Master har tre analoga utg ngar 0 10 V DC f r eventuell anslut ning av styrsignal...

Page 12: ...ktig konfigurering av de digitala ing ngarna Kontrollera och korrigera vid behov i menyn OJ Moduler Konfigurera med hj lp av din webbl ddrare Str mf rs rjningen till OJ Air Master r avst ngd Sl p str...

Page 13: ...emperatur Utekompensert tilluft Sommer vinterkompensering Resirkulering nattoppvarming Sommernattskj ling Kj leforsering Vifteregulering Konstant flow Konstant trykk Tilluftstrykk m slave Avluftstrykk...

Page 14: ...p fig 7 Analoge utganger OJ Air2 Master er utstyrt med 3 stk 0 10 V DC analoge utganger til bruk for ev tilkobling av styresignal for varmebatteri roterende varmeveksler eller spjeldmotor p kryssvarm...

Page 15: ...er elektrisk tilkobling og klemmekoblinger Feil konfigurering av digitale innganger Kontroller og rett ev konfigurasjonen under menyen OJ moduler Konfigurer ved hjelp av din nettleser Str mmen til OJ...

Page 16: ...erkompensering Recirkulering natopvarmning Sommernatsk ling K leforcering Ventilatorregulering Konstant flow Konstant tryk Indbl sningstryk m slave Udsugningstryk m slave Konstant CO2 Lav hastighed h...

Page 17: ...onteres p Dou 7 udgangen p klemmerne 36 37 Elektrisk tilslutning fremg r af fig 7 Analoge udgange OJ Air2 Master er forsynet med 3 stk 0 10 V DC analoge udgange til brug for evt tilslutning af styresi...

Page 18: ...er Forkert konfigurering af digitale indgange Kontroll r og ret evt konfigurationen under menuen OJ Moduler Konfigurer ved hj lp af din Web browser Der er slukket for sp ndingsforsyningen til OJ Air2...

Page 19: ...85 B RS485 C Aou1 Aou2 Aou3 Dou1 Dou2 Dou3 Dou4 Dou5 Dou6 Dou7 A B 1 2 FIRE Din1 Din2 Din3 Din4 Din5 Din6 VAV CO2 Ain1 VAV CO2 Ain2 24V Aou Ain2 Tin1 PT1000 Sensor Ain1 Tin2 PT1000 Sensor Aou1 Actuato...

Page 20: ...h 2 x Fan IO Fig 4 External communications ports Fig 2 Dimensions side view Fig 5 Internal communication ports Fig 6 Connections in RJ12 port for internal communication OJ Electronics A S Stenager 13B...