4.11 Measuring gas pressure
General rules for gas pressure measurement
1. Shut off the burner.
2. Open the test point connection cover.
3. Attach a silicone hose to the test point connection. Attach a gauge to the other end
of the hose.
4. Start the burner.
5. While the burner is running record gas pressure readings using the instructions
below.
6. Perform adjustments if needed.
7. Shut off the burner.
8. Finally close all the test point connections and remove measurement equipment.
Make all adjustments when the burner is running!
All stated pressure values are only for reference. The actual values may
vary depending on operating conditions.
Measuring nozzle pressure
D046520 ver. 2
1. Nozzle pressure at nominal capacity
Burner
Test point 1
(mbar)
Test point 1
(in.Wc)
50
19
7.6
90
29
11.7
Check the tables below, for adjusted pressure values.
Measuring inlet and adjusted pressure
VGG valve + SKP pressure regulator
44 (95)
M5164 1640EN