Operating Instructions 

 

Transducer for AC Voltage 

DVT-XXX(C, CX5, E, E2)

Safety precautions to be strictly observed are marked with 
following symbols in the Operating Instructions

The instruments must only be dispo-
sed of in the correct way!

Contents

  1. Read first and then  ..................................................... 8
  2. Brief description .......................................................... 8
  3. Technical data ............................................................. 8
  4. Mounting ..................................................................... 9
  5. Electrical connections ................................................. 9
  6. Commissioning and maintenance ............................. 10
  7. Releasing the transducer .......................................... 10
  8. Instruments admissions ............................................ 10
  9. Dimensional drawing ................................................. 10
10. Declarations of conformity ........................................ 11

1. Read first and then …

The proper and safe operation of the device 
assumes that the Operating Instructions is 

read carefully 

and the safety warnings given 

in the various Sections

4. Mounting
5.  Electrical connections

are 

observed

.

The device should only be handled by appropriately trained 
personnel who are familiar with it and authorised to work 
in electrical installations.
Unauthorized  repair  or  alteration  of  the  unit  invalidates 
the warranty.

2. Brief description

The transducer DVT-XXXX is designed to convert a sinusoidal 
AC voltage into a DC current or voltage proportional to the 
measured value.

3. Technical data

Measuring input  

Nominal frequency:  

50/60 Hz

Nominal input current:  0 – 50 to 0 – 600 V
Own consumption: 

<  U

N

  ·  50  µA  at  U

N

  ≤  150  V 

< U

N

 · 20 µA at U

N

 > 150 V,

 

≤ 400 V

 

< U

N

 ·   5 µA at U

N

 > 400 V

Measuring output 

DC current: 

0 - 1 to 0 - 20 mA resp. live-zero

 

0.2 - 1 to 4 - 20 mA

Burden voltage: 

15 V

External resistance: 

See Section “5. Electrical connec-
tions”

With 2-wire 
connection: 

Power supply via output leads,

 

4 - 20 mA,

 

External  resistance  see  Section  
“5. Electrical connections”

Load-independent
DC voltage: 

0 - 1 to 0 - 10 V resp. live-zero

 

0.2 - 1 to 2 - 10 V

External resistance: 

See Section “5. Electrical connec-
tions”

Response time: 

< 300 ms

Power supply 

 

AC voltage: 

24, 110, 115, 120, 230 or 400 V

 

± 15%, 50 / 60 Hz

 

Power consumption approx. 3 VA, 
see Fig. 2

Options

 

DC voltage: 

24 V, – 15 / + 33 %,

 

power consumption approx. 1.5 W, 
see Fig. 3

 

With 2-wire connection and output 

 

4…20 mA (power supply via output 
leads) 24 V, – 50/+ 33%, 

 

power consumption 1.5 W, 

 

see Fig. 4

DC or AC voltage: 

DC, AC power pack 

 

(DC or 40 - 400 Hz)

 

85 - 230 V DC/AC or

 

24 - 60 V DC/AC

 

DC – 15/+ 33%, AC ± 15%

 

Power consumption 

 

≤ 1.5 W resp. ≤ 3 VA, see Fig. 5

Accuracy 

(acc. to IEC 688)

Reference value: 

Output end value

Accuracy: 

Class 0.5

Safety

Pollution degree: 

2

Installation category:  III (with ≤ 300 V)
 

II (with > 300 V)

Reference conditions

Operating temperature: – 10 to + 55 °C
Storage temperature:  –  40 to + 70 °C
Relative humidity of
annual mean: 

≤ 75 %

Altitude: 

2000 m max.

Indoor use statement

Summary of Contents for DVT Series

Page 1: ...onvertisseur de mesure pour tension alternative DVT XXX C CX5 E E2 Operating Instructions Transducer for AC Voltage DVT XXX C CX5 E E2 OHIO SEMITRONICS INC 4242 Reynolds Drive Hilliard Ohio 43026 Tele...

Page 2: ...bedingungen Betriebstemperatur 10 bis 55 C Lagerungstemperatur 40 bis 70 C Relative Feuchte im Jahresmittel 75 Betriebsh he 2000 m max Nur in Innenr umen zu verwenden Sicherheitshinweise die unbedingt...

Page 3: ...Stromausgang den Wert Rext max k 15 V IAN mA IAN Ausgangsstromendwert nicht berschreitet bei Speisung ber den Ausgangskreis 2 Draht Technik Ausgang 4 20 mA von der Hilfsenergie H 12 32 V DC abh ngig i...

Page 4: ...ten Der Messumformer ist wartungsfrei 7 Demontage Hinweis Messumformer gem ss Bild 7 von Tragschiene abneh men Bild 7 8 Ger tezulassungen CSA gepr ft f r USA und Kanada file nr 204767 9 Mass Skizze 11...

Page 5: ...quence nominale 50 60 Hz Tension nominale d entr e 0 50 0 600 V Consommation propre UN 50 A UN 150V UN 20 A UN 150 V 400 V UN 5 A UN 400 V Sortie de mesure Courant continu 0 1 0 20 mA resp live z ro...

Page 6: ...indiqu e pour la r sistance du circuit de sortie ne doit pas tre d pass e par le haut pour la sortie de courant Rext max k 15 V IAN mA IAN Valeur finale du courant de sortie est d pendante de l alimen...

Page 7: ...imites pr vues pour les appareils num riques de classe A et la partie 15 des r glements FCC et la r glementation des radio interf rences du Canadian Department of communications Ceslimitessontdestin e...

Page 8: ...a Measuring input Nominal frequency 50 60 Hz Nominal input current 0 50 to 0 600 V Own consumption UN 50 A at UN 150 V UN 20 A at UN 150 V 400 V UN 5 A at UN 400 V Measuring output DC current 0 1 to 0...

Page 9: ...ig 6 the resistance in the output circuit may not overrange the value Rext max k 15 V IAN mA IAN current output end value with power supply via output leads 2 wire connection output 4 20 mA dependent...

Page 10: ...n tested and found to comply with the limits for a Class A digital device pursuant to both part 15 of the FCC Rules and the radio interference regulations of the Canadian Department of Communi cations...

Page 11: ...standards Nr No Richtlinie Directive 2004 108 EG 2004 108 EC Elektromagnetische Vertr glichkeit EMV Richtlinie Electromagnetic compatibility EMC directive EMV EMC Fachgrundnorm Generic Standard Messve...

Page 12: ...Directive 2004 108 EG 2004 108 EC Elektromagnetische Vertr glichkeit EMV Richtlinie Electromagnetic compatibility EMC directive EMV EMC Fachgrundnorm Generic Standard Messverfahren Measurement methods...

Reviews: