OHAUS Ranger RC Instruction Manual Download Page 7

Introduction

Ranger RC

7

1.2.1

Overview

1

Display

2

Scale specifications

3

Load plate

4

Adjustable foot

5

Keys

1

Power supply 
connection

2

Optional interface

3

RS232 interface

3

2

1

Summary of Contents for Ranger RC

Page 1: ...Instruction Manual Ranger RC Compact Scales...

Page 2: ......

Page 3: ...iner 17 3 2 Counting parts out of a container 17 3 3 Counting with variable reference quantity 18 3 4 Counting with minimum accuracy 18 3 5 Reference optimization 18 3 6 Counting with automatic refere...

Page 4: ...Ranger RC 4 Table of contents 8 Appendix 50 8 1 Information for certified scales in EC countries 50 8 2 Safety checks 50 8 3 Table of Geo Values 51 8 4 Sample protocols 54 9 Index 55...

Page 5: ...egularly and replace it immediately if it is dam aged On the rear side of the device maintain a clearance of at least 3 cm in order to prevent the mains cable bending too much CAUTION On no account op...

Page 6: ...n This user manual applies to the following types of compact scales Compact scale RC S with strain gauge weighing cell Compact scale RC M with Monobloc The compact scales are available in a small and...

Page 7: ...Introduction Ranger RC 7 1 2 1 Overview 1 Display 2 Scale specifications 3 Load plate 4 Adjustable foot 5 Keys 1 Power supply connection 2 Optional interface 3 RS232 interface 3 2 1...

Page 8: ...charge level only present on scales with a battery 7 Weight units 8 Selected reference quantity 9 Symbols for optimizing the average piece weight 10 Symbol for dynamic weighing 11 Graphic display of t...

Page 9: ...ard Transfer key Long key press Calling up menu Activating menu item Accepting selected setting Key Function Switching between gross and net weight displaying tare specification Calling up additional...

Page 10: ...al cer tification regulations These steps are not necessary for scales with an internal cali bration weight Select a stable vibration free and if possible a horizontal location The ground must be able...

Page 11: ...The battery s charging capacity can be reduced under continuous mains operation To maintain the charging capacity after a maximum of 4 weeks discharge the bat tery completely before recharging it Sca...

Page 12: ...roing corrects the influence of slight changes on the load plate Manual 1 Unload scale 2 Press ZERO The zero display appears Automatic In the case of scales that cannot be certified the automatic zero...

Page 13: ...d as the tare weight the zero display and the symbol NET appear 2 4 4 Chain tare Prerequisite The tare function CHAIn tr is activated in the menu With this function it is possible to tare several time...

Page 14: ...dy occupied and what capacity is still available In the example approx 65 of the scale capacity is occupied 2 8 Dynamic weighing With the dynamic weighing function it is possible to weigh restless wei...

Page 15: ...m a new dynamic weighing operation 2 9 Printing results If a printer or computer is connected to the scale the weighing results can be printed out or sent to a computer Press PRINT The display content...

Page 16: ...d plate holder with a solid object This could damage the weighing cell Other cleaning information Use damp cloths Do not use any acids alkalis or strong solvents Do not clean using a high pressure cle...

Page 17: ...between the number of pieces and the weight When the number of pieces is displayed it is possible to display the average piece weight with Info i e the weight of a single reference part for 2 seconds...

Page 18: ...ient to ensure the desired accuracy Add x PCS appears 3 Add the displayed number of pieces The scale then automatically determines the average piece weight with the larger reference quantity The rest...

Page 19: ...analog second scale interface The necessary settings for the application and interface parameters are described in the Sections 4 4 1 4 6 1 and 4 6 4 3 7 1 Counting with a reference scale Prerequisit...

Page 20: ...AL Ct bOtH is set in the menu the reference quantity is added to the bulk quantity 3 7 3 Counting with an auxiliary scale Note This configuration allows counting of diverse parts for example very smal...

Page 21: ...s MENU and keep it pressed untilCOdE appears 2 Press MENU again The menu item tErMINL appears Only the submenu dEVICE is accessible Supervisor menu 1 Press MENU and keep it pressed until COdE appears...

Page 22: ...Press Yes Exiting menu 1 Press Exit The last menu item END appears 2 Press Yes The inquiry SAVE appears 3 Confirm inquiry with Yes to save the settings and return to weighing mode or Press No to disca...

Page 23: ...d 10 d 27 rEStArt ON OFF 27 FILtEr VibrAt LOW MEd HIGH 27 PrOCESS UNIVEr dOSING StABILI FASt StAndrd PrECISE FACt tEMP OFF 1K 2K 3K 5K 28 Min WEiG ON OFF ON OFF 28 rESEt SUrE 28 APPLIC COUNt VAr SPL...

Page 24: ...F nEt ON OFF COnt Wt COnt Ct 2nd dISP rEF bULK AuXILIA PriNtEr tEmPLat StdArd tEMPLt1 tEMPLt2 31 ASCi Fmt LINE FMt MULtI SINGLE LENGtH 1 100 SEPArAt Add LF 0 9 PArAMEt bAUd 300 38400 32 PAritY 7 nonE...

Page 25: ...Unit 32 OUT 1 4 OFF StAbLE bEL Min AbV Min UndErLd OVErLd StAr ANALOG Mode rEF bULK AuXILIA bYPASS 32 dEF PrN tEMPLt1 tEMPLt2 LINE 1 LINE 20 NOt USEd HEAdEr SCALE NO GrOSS tArE nEt APW rEF Ct PCS StA...

Page 26: ...point 0 appears in the display The calibration weight to be placed on the scale then flashes in the display 3 If necessary change the weight value displayed with No 4 Place the calibration weight on t...

Page 27: ...ved After switching off on or after a power interruption the device continues to work with the saved zero point and tare value VIbrAt Adaptation to the ambient conditions LOW Very steady and stable en...

Page 28: ...t adjustment ON OFF Switching minimum weight function on off If the weight on the scale falls below the stored minimum weight an appears on the display in front of the weight indicator SUrE Confirmati...

Page 29: ...ing the average piece weight again OFF The average piece weight is maintained until a new average piece weight is deter mined ACCurCY Displaying the counting accuracy ON After the average piece weight...

Page 30: ...when not in use b LIGHt Switching the display backlighting on off On scales with a battery the background lighting switches itself off automatically if there has been no activity on the scale for 5 se...

Page 31: ...t GROSS Transfer of the gross weight identified with G tArE Transfer of the tare weight nEt Transfer of the net weight dt G As per dt b see above gross weight identified with G COnt Wt TOLEDO Continuo...

Page 32: ...ddress 0 31 only for NET 485 ChECSuM Activating checksum byte appears only in TOLEDO Continuous mode Vcc Switching 5V voltage e g for a bar code reader on off SUrE Confirmation inquiry Reset interface...

Page 33: ...ed to determine the average piece weight bULK Second scale can only be used as bulk scale AuXILIA No difference between reference and bulk scale all functions available on the scale selected BYPASS Se...

Page 34: ...ter which the scale changes to the next menu item KboArd KboArd Keyboard test PUSH 1 10 First press the large keys on the bottom row in order Then press the smaller keys in the top row If the key work...

Page 35: ...via the optional interface RS422 485 Up to 32 scales can be networked with the optional RS422 485 interface In network operation the scales must be addressed from the computer before commands can be...

Page 36: ...8 9 2 G SP SP SP SP SP SP SP SP SP SP SP SP SP POL W W W W W W W SP UN UN SP ST CR LF 3 T SP SP SP SP SP SP SP SP SP SP SP SP SP POL W W W W W W W SP UN UN SP CR LF 4 N SP SP SP SP SP SP SP SP SP SP...

Page 37: ...version I4 Inquiry of serial number S Send stable weight value SI Send weight value immediately SIR Send weight value repeatedly Z Zero the scale ZI Zero immediately LEVEL 1 D Write text into display...

Page 38: ...external weight TST3 Start test function with internal weight LEVEL 3 PW Average piece weight LEVEL SPECIAL I31 Header for the printout ICP Send configuration of the printout LST Send menu settings M0...

Page 39: ...3 5 2 3 Notes on network operation via the optional interface RS422 485 Up to 32 scales can be networked with the optional RS422 485 interface In network operation the scales must be addressed from t...

Page 40: ...tus Field 1 Field 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 STX SWA SWB SWC MSD LSD MSD LSD CR CHK Field 1 Field 2 STX SWA SWB SWC MSD LSD CR CHK 6 digits for the weight value that is sent withou...

Page 41: ...1 0 000X 1 1 0 0 0000X 1 1 1 Numerical increment X1 0 1 X2 1 0 X5 1 1 Status word B Status word C Function value Bit Function value Bit Gross net Net 1 0 0 0 Sign Negative 1 1 0 1 Overload 1 2 0 2 Mo...

Page 42: ...stable If necessary adjust vibration adapter or weigh dynamically Function not permissible Unload scale and set to zero Zeroing not possible with over load or insufficient load Unload scale Average p...

Page 43: ...hen back on in battery mode Call OHAUS Service Weight display unstable Restless installation location Adjust vibration adapter Draft Avoid drafts Restless weighing sample Dynamic weighing Contact betw...

Page 44: ...lectable Weighing unit selectable g kg oz lb t Taring function manual automatic chain tare Automatic zero point correction when the scale is switched on and during oper ation Filter for adapting to th...

Page 45: ...upply is interrupted the unit automatically switches over to battery operation Ambient conditions Use Altitude Temperature range RC S Temperature range RC M Overvoltage category Contamination level Re...

Page 46: ...d with optional Premium weighing cells Weighing ranges Readability certified Weighing range Readability certified 3 kg 1 5 kg 3 kg 0 5 g 1 g 3 kg 0 5 g 6 kg 3 kg 6 kg 1 g 2 g 6 kg 1 g 15 kg 6 kg 15 kg...

Page 47: ...200 46 276 208 216 RC L 1 370 360 115 350 240 52 310 304 310 1 Dimenions in mm Model without battery with battery with internal calibration weight without battery RC RS 4 6 kg 5 3 kg RC LS 8 2 kg 8 9...

Page 48: ...y operated as RS422 or RS485 RS232 Ethernet RS232 USB RS232 Digital I O RS232 Analogsecond scale interface Pin RS232 COM1 COM2 RS422 4 wire COM1 RS485 2 wire COM1 Digital I O COM2 Analog Interface 1 G...

Page 49: ...e Cover for RC L 21203720 RS232 Cable for PC 80500525 RS232 Cable for Second Scale RS232 Cable for SF42 Printer Anti theft Device Carrying Case for RC R Carrying Case for RC L Printer 80500526 8085000...

Page 50: ...s according to EN45501 8 2 2 Scales with analog connec tion to the weighing platform require an additional test according to EN45501 3 5 3 3 However this test is not mandatory if the terminal bears th...

Page 51: ...ountries Geographical latitude Geo value Country 46 22 49 01 18 Austria 49 30 51 30 21 Belgium 41 41 44 13 16 Bulgaria 42 24 46 32 18 Croatia 48 34 51 03 20 Czechia 54 34 57 45 23 Denmark 57 30 59 40...

Page 52: ...Slovenia 36 00 43 47 15 Spain 55 20 62 00 62 00 69 04 24 26 Sweden 45 49 47 49 18 Switzerland 35 51 42 06 16 Turkey 49 00 55 00 55 00 62 00 21 23 United Kingdom factory setting Geographical latitude G...

Page 53: ...45 26 45 9 23 54 29 25 10 26 45 31 56 11 29 25 34 21 12 31 56 36 41 13 34 21 38 58 14 36 41 41 12 15 38 58 43 26 16 41 12 45 38 17 43 26 47 51 18 45 38 50 06 19 47 51 52 22 20 50 06 54 41 21 52 22 57...

Page 54: ...5 d RESTART OFF FILTER VIBRAT MED PROCESS UNIVEr StABILI StAnDrD Min WEiG SEt VAL 0 000 g ONOFF OFF APPLICATION COUNT VAr SPL Spl Qty SQ1 5 SQ2 10 SQ3 25 SQ4 50 SQ5 100 Min RefW 99 REF OPT OFF A SMPL...

Page 55: ...3 Scale 26 Terminal 30 Menu structure 22 Minimum accuracy 18 O Operator menu 21 Options 6 32 P Password 21 Power supply 11 Protocol 15 Q Quantity scales 20 R Readability 46 Reference determination aut...

Page 56: ...nt or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than Ohaus In lieu of a prop...

Page 57: ......

Page 58: ...us Corporation 19A Chapin Road P O Box 2033 Pine Brook NJ 07058 USA Tel 973 377 9000 Fax 973 844 7177 www ohaus com with offices worldwide P N 22017167 2007 Ohaus Corporation all rights reserved Print...