Ranger™ Count 2000 Series EN-25
5. LEGAL FOR TRADE
When the scale is used in trade or a legally controlled application it must be set up,
verified and sealed in accordance with local weights and measures regulations. It is
the responsibility of the purchaser to ensure that all pertinent legal requirements are
met.
The Menu Lock switch limits changes to the Cal, Setup, Readout, Unit and Print
menus. The switch in type approved models may set some scale settings as
required by the approval agency. The switch may be secured using paper seals,
wire seals or plastic ties.
Note:
When LEGAL FOR TRADE is set to ON (LFT Switch in locked position), the
menu settings are affected as follows:
Calibration (
C.A.L
) menu is not accessible.
Unit is locked at its current setting.
Zero Range setting is locked at 2%.
Stable Range setting is locked at 1d.
Auto-Zero Tracking setting is locked at 0.5d.
Stable Only is locked On.
Auto Print/ Continuous is disabled
lb:oz is locked Off.
5.1 Settings
Before verification and sealing, perform the following steps:
1. Verify that the menu settings meet the local weights and measures regulations.
2. Perform a calibration, see section 4.2.
3. Set the switch to Locked. See figure 5-1.
5.2 Verification
The local weights and measures official or authorized service agent must perform
the verification procedure.
5.3 Sealing
The local weights and measures official or authorized service agent must apply a
security seal to prevent tampering with the settings. Refer to the illustration below
for sealing methods.
Figure 5-1. Sealing
Paper Seal
Wire Seal
Unlocked Locked with Paper Seal Locked with Wire Seal
Lock Switch
Wire Seal