www.oes-scoreboards.com | 1.877.652.5833
4056 Blakie Rd., London ON Canada N6L 1P7
Rev: ISC9000_j12.0_1.3
Issued: 2021-10-21
Page 36 of 44
•
To SET segment times
o
Press “SHIFT/SEG” or “SHIFT” button until the cursor appears in INT (S) field.
o
Enter second’s value for intermissions between segments.
o
Press ENTER button to move to the SEG field
o
Use CLEAR button to toggle between SEG/1>> (“1>>” will show the relative number of the
segment: i.e when running segments 6, 7, 8, the segment number displayed on the scoreboard
will scroll through 1, 2, 3. “SEG” will show the absolute segment number from the 0-99 memory
slots available: i.e when running segments 6, 7, 8, the segment number displayed on the
scoreboard will scroll through segments 6, 7, 8)
o
Press ENTER to move the cursor to the SEGMENT field.
o
Enter value on numeric keypad of the segment desired to be modified.
Maximum value is: 99
o
Press ENTER.
o
Enter minutes of the timer value on numeric keypad.
o
Press ENTER.
o
Enter seconds of the timer value on numeric keypad.
o
Press ENTER.
Maximum value is: 59 minutes and 59 seconds.
o
Enter Horn length in seconds on numeric keypad.
Maximum value is: 9 seconds. (Enter “0” for no horn)
o
Press ENTER.
o
Repeat for all segments to be modified.
•
To RUN segment timers
o
Press “SHIFT/SEG” or “SHIFT” button until the cursor appears in RUN FIRST field.
o
Enter value of the desired FIRST segment to be run in sequence using the numeric keypad.
o
Press ENTER.
o
Enter value of the desired LAST segment to be run in sequence using the numeric keypad.
o
Press ENTER.
o
Use the “RUN” button controller to start the FIRST segment. All selected segments will run
consecutively until the LAST segment has expired. The “CURRENT” value on the controller display
will show the current segment running, and switch between “RUN” and “INT” to show whether a
segment is running or an intermission is running.
•
To EXIT SEGMENT TIMER, push and hold “SHIFT/SEG” or “SHIFT” button.