10
Detergent Mode (Option – Injector Kit)
Only detergents approved by OERTZEN to be used. Warranty
will expire in case hazardous detergents or detergents not
approved by OERTZEN will be used
.
Put detergent hose with strainer into a vessel with detergent liquid.
Turn handle at the double lance counter-clockwise. Detergent is sucked
into low pressure stream and applied onto the cleaning object.
Detergent to work in, but must not dry.
Turn handle at the double lance clockwise. Detergent stream is
interrupted. Rinse cleaning object with water jet.
After finishing detergent mode, suction line to be flushed
thoroughly to avoid detergent residues
.
High Pressure Pipe Cleaning (Option)
During the pipe cleaning procedure aerosols may be formed, so
that wearing a protective mask is recommended.
Push pipe cleaning hose with nozzle into the pipe up to the marking
(approx. 50 cm).
Open stop valve and start unit by means of the ON/OFF switch (2). The
pipe cleaning nozzle is automatically drawn in due to the recoil effect.
As soon as the nozzle hits the clogging, carefully pull back the hose and
let it move in again, in order to flush out the clogging. Work in sections
and avoid excessive dirt removal, in order to avoid that the pipe is
clogged again.
During removal of the pipe cleaning hose stop machine as soon as
the marking is reached (approx. 50 cm before the end is reached),
as otherwise the hose would flap around so causing severe
injuries. If no marking is detected, apply one by means of coloured
tape or paint.