English 16
English
As shown here, after the
TIG torch trigger is
quickly pressed and
released from step 3A, it
is possible to press and
hold the TIG torch
trigger another time to
end the downslope time
and maintain the output
current at the Crater
current. When the TIG
torch trigger is released
the output will turn OFF.
This sequence
operation, 4-step with restart disabled, is the default
setting from the factory.
4-Step Trigger Sequence with Restart Option
To select 4-Step with restart sequence:
Output
Visualization
Press several times until the LED above lights up
Enter Menu GTAW and enable 4RST option.
If 4-step restart is enabled from the setup menu the
following sequence will occur for steps 3 and 4 (steps 1
and 2 are not altered by the restart option):
3. Press and hold the TIG torch trigger. The machine
will now decrease the output current at a controlled
rate, or downslope time, until the Crater current is
reached.
4. Release the TIG torch trigger. The output current will
again increase to the Welding current, like in step 2,
to continue welding.
If the weld is completely finished, use the following
sequence instead of step 3 described above.
3A. Quickly press and release the TIG torch trigger.
The machine will now decrease the output current at
a controlled rate, or downslope time, until the Crater
current is reached and the output of the machine is
turned OFF. After the arc is turned OFF the postflow
time will start.
As shown here, after
the TIG torch trigger is
quickly pressed and
released from step 3A,
it is possible to press
and hold the TIG torch
trigger another time to
end the downslope
time and maintain the
output current at the
Crater current. When
the TIG torch trigger is
released the output will
again increase to the
Welding current, like in step 4, to continue welding.
When the main part of the weld is complete go to step 3.
As shown here, again
after the TIG torch
trigger is quickly
pressed and released
from step 3A, it is
possible to quickly
press and release the
TIG torch trigger a
second time to end the
downslope time and
stop welding.
Spot TIG (GTAW welding)
Enter in Menu GTAW to enable spot welding function.
When enabled, the spot tig function replaces the 2S
trigger sequence.
To select Spot function:
Output
Visualization
Press until the LED above lights up
This welding mode is especially thought to tack or weld
thin materials.
It uses HF start and immediately It delivers the set
current without any upslope/downslope.
When spot is selected automatically you have this
setting:
2S
without
restart
Working only in HF mode
Upslope and downslope are disabled
When spot is selected in left display without any
welding operation you can see the text:
S-0.0
While right displays shown the set current.
For default the spot time is 0s: that means the output
current is delivered only when the trigger button is
pushed.
The welding time is set with the spot time control and will
be constant independently from the operation of the
Trigger.
To set the spot time, user has to push SEL button until
text SPT appears on the left display: turning now the
main know is possible to set SPT time from 0 to 100s
Summary of Contents for CITOTIG 315
Page 2: ......
Page 333: ...I 12 05 1 2 4 5 7 Waste Electrical and Electronic Equipment WEEE 28 28 REACh 28 28 28 29...
Page 337: ...4 01 11 IEC 61000 3 12 Ssc 2227 Ssc 2227 A...
Page 338: ...5 01 11 Oerlikon CE 2006 25 EC EN 12198 2 15 EN169...
Page 339: ...6 30 HF TIG GTAW TIG GTAW 85 8...
Page 342: ...9 COOLER COOL SYS 30 6 7 D TIG E COOLER 400 COOLER Power ON TIG...
Page 345: ...12 5 A 9 1 2 1 M 1 SAVE 2 M 2 RECALL 3 M 3 MEM SET 3 3 3 MEM SAVE 1 2 3 3...
Page 348: ...15 TIG TIG 2 4 2 2 2 TIG 1 TIG 25 LIFT 2 TIG 2 2 2 GTAW 2RST 2...
Page 349: ...16 1 2 4 4 4 1 LIFT 25 A 1 2 2 3 4 TIG 3 4 4 4 GTAW 4RST 4 3 4 1 2...
Page 350: ...17 3 4 2 3 3A TIG 3 4 3 TIG 3 TIG GTAW GTAW TIG 2S 2 S 0 0 0 SEL SPT SPT 0 100...
Page 351: ...18 Set A2 GTAW BILV TIG 4S B 0 0 4S 1 2 3 Set A2 3A 2 SEL A2 2 TIG LIFT TIG ON TIG ON...
Page 356: ...23 MANL TSTR Tig C 2S 4S GTAW...
Page 429: ......