C
85-340
Boiler Assembly - Installation & Operation Instructions
│
Odyssey
11
Figure 4-9 Attach HydroStat 3250 Bracket
Figure 4-10 Attach Back Panels & Electro-well
Figure 4-11 Install Ground Wire and Sensor
Figure 4-12 Install Top and Front Covers
Sensor - Insert the sensor fully into the Electro-well
or the boiler may overheat resulting
in fire, property damage, serious injury, or death.
Attach the control
panel between the
side panels, secure
the HydroStat 3250
to the control panel
as shown.
HydroStat
3250
Control Panel
Secure bottom back panel.
Attach hold down bracket
to top edge of HydroStat
control panel to secure it
in place.
Recommend installing
top back after flue
breeching connected
and sealed.
Hold Down
Bracket
Ground Wire - Connect green
wire between ground screw
and HydroStat ground screw.
Sensor - Insert fully into the
Electro-well
or overheating
may occur. See “Danger”.
Ground Screw
Electro-well
Installation of burner and
completion of wiring
must be done
with front
cover removed.
See Figure 4
-11