EXPLORE
E7
2 0 1 9 I N S T A L L & O P E R A T I O N M A N U A L
30
6.5 CABLE GAUGE CHART 24V
Supply & Return Cable Conductor Size Chart 3% drop for when using 24V DC supply
Cable
length
(feet)*
Circuit Current
2 Amp
4 Amp
6 Amp
8 Amp
10 Amp
15 Amp
20 Amp
25 Amp
30 Amp
40 Amp
50 Amps
0-5
18 AWG
18 AWG
18 AWG
18 AWG
18 AWG
16 AWG
14 AWG
14 AWG
12 AWG
12 AWG
10 AWG
5-10
18 AWG
18 AWG
16 AWG
16 AWG
14 AWG
12 AWG
12 AWG
10 AWG
10 AWG
8 AWG
8 AWG
10-15
18 AWG
16 AWG
14 AWG
14 AWG
12 AWG
12 AWG
10 AWG
8 AWG
8 AWG
6 AWG
6 AWG
15-20
18 AWG
16 AWG
14 AWG
12 AWG
12 AWG
10 AWG
8 AWG
8 AWG
6 AWG
6 AWG
4 AWG
20-25
18 AWG
14 AWG
12 AWG
12 AWG
10 AWG
8 AWG
8 AWG
6 AWG
6 AWG
4 AWG
4 AWG
25-30
16 AWG
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
4 AWG
2 AWG
30-35
16 AWG
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
4 AWG
2 AWG
35-40
16 AWG
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
40-45
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
4 AWG
4 AWG
4 AWG
2 AWG
2 AWG
45-50
14 AWG
12 AWG
10 AWG
8 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
50-55
14 AWG
12 AWG
10 AWG
8 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
55-60
14 AWG
10 AWG
10 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
60-65
14 AWG
10 AWG
8 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
65-70
14 AWG
10 AWG
8 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
70-75
12 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
2 AWG
2 AWG
2 AWG
0 AWG
0/2
AWG
75-80
12 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
80-85
12 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
85-90
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
90-95
12 AWG
8 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
1 AWG
1 AWG
0/2
AWG
0/2
AWG
95-100
12 AWG
8 AWG
6 AWG
6 AWG
4 AWG
2 AWG
2 AWG
1 AWG
0 AWG
0/2
AWG
0/3
AWG
*One-way cable length from supply (usually battery) to load.