PROBLEM
CHECK
CAUSE
FIX
Light does
not light up
Check that the electrical
connections between the
light and the supply cable
have been made correctly
Poor electrical
connection
Remake connection and
seal joint correctly
Check that the wiring
polarity is correct, red to
positive and black to
negative
Polarity incorrect
Change the wiring
polarity and seal joint
correctly
Check that there is power
supply to the light cable
connection
Poor electrical
connection
Trace the cables back,
checking at joints until
break has been located.
Then rectify the problem
and seal joint correctly
Check that the electrical
connections between the
supply cable and the light
circuit breaker or fuse have
been made correctly
Poor electrical
connection
Remake connection and
seal joint correctly
Check that the in-line
fuse is intact and not
blown
Replace fuse
If fuse keeps blowing, then
there is a short circuit in the
light system that must be
traced and rectified. If no
external short can be
located contact your dealer
Exchange the power cable
(between light and power
supply) with one from a
working light
Light works, faulty cable
Contact your dealer for a
replacement cable
Check that the light supply
circuit breaker is closed, or
the fuse has not blown
Close circuit breaker
/ replace fuse
If breaker / fuse keeps
blowing, then there is a
short circuit in the light
system that must be
traced and rectified. If no
external short can be
located contact your
dealer