7
MAXIMUM WATER LEVEL
4” FROM TOP OF TANK
This Side Up
FRONT
CONDENSATE TANK
“FULL”
SWITCH
SPRING
CAP
HANDLE
WATER LEVEL
ADJUSTMENT
SCREW
HINGE
CONDENSATE TRAY
TANK LEVEL ADJUSTMENT INSTRUCTIONS
An adjustment screw is provided to vary the cut-off level
of the tank full switch. If less water is desired, turn the
adjusting screw clockwise
(CW).
Turning the screw clockwise (CW),
will make the tank easier to remove.
MAXIMUM WATER LEVEL
4” FROM TOP OF TANK
CAUTION
UNPLUG UNIT BEFORE REMOVING
TANK TO ADJUST THE SET SCREW
.
CONDENSATE
SUMP
TOP OF TANK
(WHEN PLACED IN UNIT)
SUMP DRAIN HOLE
“CON”
WILL BE
DISPLAYED
CONDENSATE
For Models PAC1211, PAC1811, PAC2412, AND PAC3612, a 5-gallon polyethylene tank
is provided to collect condensate. The tank is located in the lower front section of the unit,
and can be accessed though the condensate tank door. When the high water level is
reached, a cut-out switch will AUTOMATICALLY cycle off the compressor/condenser fan.