![Observint BLK-PTZ36XIR User Manual Download Page 29](http://html2.mh-extra.com/html/observint/blk-ptz36xir/blk-ptz36xir_user-manual_3191520029.webp)
21
36x PTZ IR Outdoor Camera User Manual
SECTION 4: USING THE OSD MENUS
System Information settings
NOTE
Using an internet browser connected to a DVR, click the left and right direction buttons in the PTZ control panel to page up
or page down when more than one page is available.
Descriptions of system parameter configuration:
•
Dome address settings
TASK 1: Set the soft address of the camera.
If the
SOFT ADDR ACTIVE
is set ON, the soft address is the valid address for connecting the camera. The
SOFT
ADDRESS
ranges from 1 to 255.
If the
SOFT ADDR ACTIVE
is set as OFF, the hard address set by the DIP switch is the valid address of the camera.
TASK 2: Set the broadcast address of the camera.
When the
BROADCAST ADDRESS
is set to ON, the control devices with address 0 can control the camera remotely
regardless of the address of the camera.
With this function on, a control device with address 0 can control all PTZ cameras connected to it. This function is
usually used for debugging.
•
Soft baud rate settings
If the
SOFT BAUD ACTIVE
is set to ON, the soft baud rate is the valid baud rate for the camera. You can select either 2400,
4800, 9600 or 19200.
If the
SOFT BAUD ACTIVE
is set to OFF, the baud rate is set by the SW2 DIP switches.