6 | EN

OBO Bettermann

Intended use

1 5 

Basic standards and regulations

 

– IEC 61851-1

 

– IEC 62196-2

1 6 

Applicable documents

 

– Declaration of conformity

 

– Mounting instructions, Ion charging stations (for electrical installation 

engineers)

2  Intended use

As a sole charging point, the Ion charging station is only intended for 

charging electric vehicles in private areas with restricted access, e.g. 

private land. The charging station is only suitable for permanent mount-

ing on the wall in interior or protected exterior areas. Charging takes 

place according to Mode 3 in accordance with IEC 61851-1 with a type 2 

connector for charging single-phase, dual-phase or triple-phase electric- 

al vehicles with 11 kW/16 A (factory setting).
Charging electric vehicles with gassing batteries is not permitted.
The charging station is not designed for any use other than that de-

scribed here. If the charging station is used for another purpose, then 

this shall render all liability, warranty and damage claims null and void.

3  Safety

3 1 

General safety information

Observe the following general safety information:

 

 

Contact with electrical current can lead to an electric shock. Only 

electrical technicians may open the charging station and carry out 

electrical work.

 

– If the device presents defects or damage, then this can cause a fire 

or people could be injured by an electric shock. Only use devices in 

perfect condition. If you detect defects or damage, then switch off/de- 

energise the charging station using the buildings fuse.

 

– Keep children and animals away from the system.

 

– People with heart pacemakers or defibrillators may not work on, or be 

located in the vicinity of, charging systems and their equipment, e.g. 

for maintenance purposes or for troubleshooting.

3 2 

Safety stickers

List of safety stickers attached to the device and their meaning: 

Danger of electrical voltage!

  

Ensure de-energisation before working on the device.

Electrical technician!

 

Only electrical technicians may mount and connect the device.

Protection class!

The device corresponds to Protection Class 1 according to DIN EN 61140 

(VDE 0140-1).

Summary of Contents for Ion Basic

Page 1: ...OBO Bettermann Holding GmbH Co KG Operating instructions Ion Basic charging station Ion Key charging station Ion Basic Protect charging station Ion Key Protect charging station...

Page 2: ...2023 OBO Bettermann Holding GmbH Co KG Ion Basic charging station Ion Key charging station Ion Basic Protect charging station Ion Key Protect charging station Operating instructions...

Page 3: ...e documents 6 2 Intended use 6 3 Safety 6 3 1 General safety information 6 3 2 Safety stickers 6 4 Product overview 7 4 1 Accessories 8 4 2 Product description 8 5 Mounting and installation 9 6 Chargi...

Page 4: ...4 EN OBO Bettermann Table of contents...

Page 5: ...documents supplied with the product must be stored in an easily accessible location so as to be available when information is required The current version of the operating instructions can also be op...

Page 6: ...all liability warranty and damage claims null and void 3 Safety 3 1 General safety information Observe the following general safety information Contact with electrical current can lead to an electric...

Page 7: ...g station 1 Charging station 2 Front panel 3 Charging station status LED 4 Surge protection status LED 5 On off switch without authorisation On off switch with authorisation key switch 6 Charging conn...

Page 8: ...on cover otherwise available separate ly 2034680 4 2 Product description The Ion charging stations are intended for charging electric vehicles in private areas as a sole charging point The charging st...

Page 9: ...appropriate mounting and installation instructions for electrical in stallation engineers are included with the product 6 Charging an electric vehicle Risk of electric shock If the device presents de...

Page 10: ...the charging station as possible so that the charging cable is not taut No adapter connectors or extensions may be used Fig 2 3 4 Charging an electric vehicle 4 Connect the charging connector to the...

Page 11: ...ends the charging operation automatically Status LED is continuously blue again 6 Release the charging connector from the vehicle 1 and reattach the protective cap 7 Wind the charging cable on the ca...

Page 12: ...he on off switch or key switch Restart the charging operation after 2 hours Charging station is defective Contact the electrical technician installa tion engineer Safety fuse has tripped Contact the e...

Page 13: ...n variants the surge protection installed in the charging station must be disconnected before the inspection 9 1 Checking the function The perfect function of the charging station can be checked using...

Page 14: ...The charging power of the Ion charging station is lower than expected What could be the reason Check whether a limitation of the charging power was set in the ve hicle refer to the operating instructi...

Page 15: ...EN 15 Notes...

Page 16: ...termann Holding GmbH Co KG P O Box 1120 58694 Menden GERMANY Customer Service Germany Tel 49 0 2373 89 1700 Fax 49 0 2373 89 1238 E mail info obo de www obo bettermann com OBORD 210684 HAFA 49523540 0...

Reviews: