- EN -
57
5.2.3 Setting the filter pump status detection
N O T E
Setting is only necessary in the following circumstances:
►
The installation height of the filter container differs from the system-specific requirements.
(
→
Installation and connection)
►
The admissible frictional resistances in the supply lines differ considerably from those
specified.(
→
Technical data)
The filter pump status detection signals via the system message
Er88
if the filter pump is operating
correctly. The system message
Er88
is not triggered unless the status detection is activated for 10 minutes
continuously. This prevents brief fluctuations in the water level from triggering the system message
Er88
.
Check the setting according to the water level in the filter container and correct it if necessary to ensure
that the status detection signals correctly. In addition, the losses in the supply line due to the filter pump
must be at least 3.5 mbar (3.5 cm).
►
The status detection can be deactivated if necessary. (
→
E7
: Pump status detection)
How to proceed:
S
1. Remove the container cover.
– The filter drum is stopped for safety reasons if the filter cover is lifted and
Er11
is indicated in the
display of the control system.
2. Switch off the filter pump.
3. Switch off the mains voltage (ensure that the control system is isolated).
4. Measure
the
distance
between the top edge of the container and the level of the water and determine
the necessary position of the holder according to the table.
5. If the determined position differs from the current position, correct it as required
– Undo and remove both screws of the holder. Push the holder into the correct position and fasten
with both screws.
6. Fit the container cover.
7. Switch on the control system and filter pumps and check the function of the status detection.
The status detection is correctly set when the float sinks with the filter pump switched on and the system
message
Er88
is only triggered 10 minutes after the filter pump is switched off.
S
Water level in the filter container/pond
(measured from the top edge of the container with the filter pump
switched off)
max. min.
139 mm
159 mm
9
132 mm
152 mm
8
125 mm
145 mm
7
118 mm
138 mm
6
111 mm
131 mm
5
104 mm
124 mm
4
97 mm
117 mm
3
90 mm
110 mm
2 1)
83 mm
103 mm
1
1) Factory setting
Summary of Contents for ProfiClear Premium Compact EGC
Page 2: ... 2 A ProfiClear0100 ...
Page 3: ... 3 B ProfiClear0101 C D yy ProfiClear0103 ProfiClear0102 E ProfiClear0081 ...
Page 4: ... 4 F ProfiClear0082 G ProfiClear0112 ...
Page 5: ... 5 H BTC0027 I J BTC0019 BTC0022 ...
Page 6: ... 6 K ProfiClear0040 L ProfiClear0047 M ProfiClear0109 ...
Page 8: ... 8 S ProfiClear0110 T PrifiClear0083 U BTC0025 ...
Page 9: ... 9 V ProfiClear0084 W ProfiClear0085 X Y BTC0023 BTC0024 ...
Page 10: ... 10 Z ProfiClear0104 ...
Page 372: ...47627 01 17 ...