![Oase ProfiClear Premium Compact EGC Operating Instructions Manual Download Page 60](http://html.mh-extra.com/html/oase/proficlear-premium-compact-egc/proficlear-premium-compact-egc_operating-instructions-manual_720353060.webp)
- EN -
60
6.5.2
EC
: Extended cleaning time "Extra Cleaning"
To prevent larger deposits from building up in the dirt channel or pipework, the unit performs a cleaning
cycle with an extended cleaning time after every 20 cleaning cycles. This ensures that the pipework is
flushed out at regular intervals.
However, if dirt and residue build up due to unfavourable conditions, you can increase the cleaning time
and flush out the pipe with additional water. The default setting for the extended cleaning time is 20 s.
How to proceed
Information
1.
Press
several times until
EC
appears in
the display.
To cancel and exit the menu: Either wait for 10 s or press
or
.
2.
Press
for 5 s until the cleaning time is
indicated in the display.
To cancel and exit the menu: Either wait for 5 s or press
or
.
3.
Press
several times to change the
value.
To change the value quickly: Hold down
the button.
Settable range: 10 – 60 s
Increment: 1 s
The number can only be changed upwards. Once the value 60 is
reached, the display returns to 10.
Saving the set value: Wait for 5 s until the menu is automatically exited.
Cancel without saving and exit the menu: Press
or
.
6.5.3
In
: Time-dependent cleaning "Interval"
In addition to automatic cleaning, the unit can also perform a time-dependent cleaning cycle. This is
particularly useful for ponds containing fish because even if there is only a small amount of dirt, excrement
is always removed from the water cycle before it leads to a build-up of nutrients.
Adjust the time interval to meet the requirements. The Drum Filter Module is normally optimally set with a
time interval of 20 minutes (default setting). The function is deactivated with a time setting of 0 minutes.
The time-dependent cleaning cycle does not have any influence on the automatic cleaning cycle that starts
when the water level is too low. After each automatic cleaning cycle, the time interval is reset and starts
again from the beginning.
N O T E
The time-dependent cleaning cycle also protects the filter system from freezing. For this, please refer to
the information about safe overwintering. (
→
Storage/overwintering)
Proceed as follows
Information
1.
Press
several times until
In
appears in
the display.
To cancel and exit the menu: Either wait for 10 s or press
or
.
2.
Press
for 5 s until the time is indicated in
the display.
To cancel and exit the menu: Either wait for 5 s or press
or
.
3.
Press
several times to change the
value.
To change the value quickly: Hold down
the button.
Settable range: 0.3 – 60 min
0 min: No time-dependent cleaning
Increment: 1 min
The number can only be changed upwards. Once the value 60 is
reached, the display returns to 0.
Saving the set value: Wait for 5 s until the menu is automatically exited.
Cancel without saving and exit the menu: Press
or
.
Men
u
On
|
O
ff
C
l
ean
Men
u
On
|
O
ff
C
l
ean
Men
u
On
|
O
ff
C
l
ean
Men
u
On
|
O
ff
C
l
ean
Men
u
On
|
O
ff
C
l
ean
Men
u
On
|
O
ff
C
l
ean
Summary of Contents for ProfiClear Premium Compact EGC
Page 2: ... 2 A ProfiClear0100 ...
Page 3: ... 3 B ProfiClear0101 C D yy ProfiClear0103 ProfiClear0102 E ProfiClear0081 ...
Page 4: ... 4 F ProfiClear0082 G ProfiClear0112 ...
Page 5: ... 5 H BTC0027 I J BTC0019 BTC0022 ...
Page 6: ... 6 K ProfiClear0040 L ProfiClear0047 M ProfiClear0109 ...
Page 8: ... 8 S ProfiClear0110 T PrifiClear0083 U BTC0025 ...
Page 9: ... 9 V ProfiClear0084 W ProfiClear0085 X Y BTC0023 BTC0024 ...
Page 10: ... 10 Z ProfiClear0104 ...
Page 372: ...47627 01 17 ...