![Oase ProfiClear Premium Compact EGC Operating Instructions Manual Download Page 61](http://html.mh-extra.com/html/oase/proficlear-premium-compact-egc/proficlear-premium-compact-egc_operating-instructions-manual_720353061.webp)
- EN -
61
6.5.4
E7
: Pump status detection
The pump status detection signals via the system message
Er88
if the pump is operating correctly. The
status detection is activated in the default setting.
Proceed as follows
Information
1s
t
Press
several times until
E7
appears in
the display.
To cancel and exit the menu: Either wait for 10 s or press
or
.
2
n
d
Keep
pressed for 5 s until the value 0 or
1 is indicated in the display.
To cancel and exit the menu: Either wait for 5 s or press
or
.
3r
d Press
to change the value.
Settable range: 0 or 1
0: The pump status detection is deactivated.
1: The pump status detection is activated.
Cancel without saving and exit the menu: Press
or
.
6.6
Reading out the number of cleaning cycles
6.6.1 Cleaning cycles in 24 hours
How to proceed
Information
Press
and
for 5 s.
The sum of the automatic and time-dependent cleaning cycles is saved.
The 4-digit value is displayed by two groups of two digits that appear in
succession in the display.
Example:
01-17
: Corresponds to 117 cleaning cycles
The number is repeated five times after an extended pause to make it
easier to read:
01-17---01-17---01-17---01-17---01-17
Note:
If the mains voltage is switched off, the counter is reset to 0.
6.6.2 Total cleaning cycles
How to proceed
Information
Press
and
for 5 s.
The sum of the automatic, manual and time-dependent cleaning cycles is
saved. The 8-digit value is divided into four groups of two digits that appear
in the display in succession.
Example:
00-00-12-44
: Corresponds to 1244 cleaning cycles
The number is repeated four times after an extended pause to make it
easier to read:
00-00-12-44---00-00-12-44---00-00-12-44---00-00-12-44
Note:
If the mains voltage is switched off, the number of cycles is rounded off to
the nearest hundred and saved.
6.7
Loading default settings
How to proceed
Information
Press
and
for 10 s until
rE
appears in
the display.
All individually set values will be overwritten!
The following values are set:
Cleaning time
CL
: 10 s
Extended cleaning time
EC
: 20 s
Interval of the time-dependent cleaning
In
: 20 min
Men
u
On
|
O
ff
C
l
ean
Men
u
On
|
O
ff
C
l
ean
Men
u
On
|
O
ff
C
l
ean
Men
u
C
l
ean
On
|
O
ff
C
l
ean
On
|
O
ff
Men
u
Summary of Contents for ProfiClear Premium Compact EGC
Page 2: ... 2 A ProfiClear0100 ...
Page 3: ... 3 B ProfiClear0101 C D yy ProfiClear0103 ProfiClear0102 E ProfiClear0081 ...
Page 4: ... 4 F ProfiClear0082 G ProfiClear0112 ...
Page 5: ... 5 H BTC0027 I J BTC0019 BTC0022 ...
Page 6: ... 6 K ProfiClear0040 L ProfiClear0047 M ProfiClear0109 ...
Page 8: ... 8 S ProfiClear0110 T PrifiClear0083 U BTC0025 ...
Page 9: ... 9 V ProfiClear0084 W ProfiClear0085 X Y BTC0023 BTC0024 ...
Page 10: ... 10 Z ProfiClear0104 ...
Page 372: ...47627 01 17 ...