Operating modes 

The ProfiClear Classic module filter can be configured and installed in many ways. In the following, two operating 
modes are described: the "principle of gravity" and the "pumped system". Please contact a specialist for all other 
operating modes and special requirements! 

 

Principle of gravity (A) 

The filter system (M 1/ M 2/ M 3/ M 4) is completely buried. Soiled pond water enters the first filter module (M 2/ M 3/ M 
4) by gravity by passing the bottom drain. In the pump chamber (M 1) the pump is located at the end of the systems 
and returns the cleaned water into the pond. 
Advantages of the principle of gravity: 

  efficient removal of suspended matter because the dirt enters the coarse dirt separating module (M 2) without being 

pumped 

  low energy requirement due to negligible height differences and low frictional loss 

  The filter system can be easily hidden 

 

Pumped systems (B) 

The filter system (M 2/ M 3/ M 4) can be placed above the pond water level. Soiled pond water is fed out of the pond 
(or out of the levelled pump chamber M 1) and into the filter system using a pump. The cleaned water is returned to the 
pond by gravity, passing a pipe. 
Advantages of the pumped systems: 

  easily retrofittable to existing ponds 

  low installation requirement 

  the system can be easily extended 

 

Module installation (planning aid) 

Important! In swimming ponds, the filter pump must be positioned outside of the pond, and always below the 
pond water level. Otherwise danger of running dry and, as a result, damage to the filter pump! 

 

Principle of gravity (A) 
Dig a pit of sufficient size to accommodate the filter system (M 1/ M 2/ M 3/ M 4). For the dimensions/execution, 
take the following into account: 

  distance from the pond edge (A-1) which cannot be flooded and conforms with the regulations. It is not permitted to 

install units operated with a rated voltage of 230 V in swimming ponds. Observe a minimum distance between units 
and pond (e.g. in Germany 2 m, in Switzerland 2.5 m etc.) 

  that the inlet sockets must be located 

below

 the pond water level, such that the minimum water level in the container 

is 630 mm above the pit bottom (A-3). Otherwise the pond water cannot drain and cleaned in the filter system. Dan-
ger of running dry and, as a result, damage to the filter pump! 

  that the overflow openings in the internal covers of the module containers are located 

above

 the pond water level 

and that the maximum water level in the container is 730 mm above the pit bottom (A-2). This is particularly impor-
tant, otherwise the filter cannot reach its maximum peformance, and, above all, because of the danger of fully emp-
tying the pond! 

Important! Put the system out of operation if the min./max. values (A-3 and A-2) are exceeded, and especially 
when fallen below. This means that the maximum permissible range of pond water level fluctuation is 100 mm. 

Furthermore, take the following into account: 

  the thickness of the slab accommodating the modules has to be adapted to the local ground situation 

  ensure sufficient space for possible system extensions 

  ensure sufficient room for movement to be able to carry out cleaning and maintenance work. 

Secure the walls of the pit against ground soil settling (masonry, concrete) and provide a rain water drain. Place the 
filter system (M 1/ M 2/ M 3/ M 4) with a 30 mm gravity in flow direction on a stable and level ground (at least slabs, 
concrete to be preferred). Due to the considerable volume, the weight of the filter modules in accordance with the 
technical data has to be taken into consideration when selecting the base. For this operating mode, install a dry run-
ning protection (commercial float switch) in the pump chamber M 1 which switches off the filter pump should the water 
level drop too low due to soiled filter modules. 

Summary of Contents for ProfiClear Classic

Page 1: ...ProfiClear Classic 18155_GAW_ProfiClear_Classic_end 05 10 11 16 07 Seite 2 ...

Page 2: ...2 ...

Page 3: ...3 ...

Page 4: ...4 ...

Page 5: ...5 ...

Page 6: ... ProfiClear Classic in the following termed unit and all other parts from the delivery scope may be used exclusively as follows For mechanical and biological cleaning of garden ponds Operation under observance of the technical data The following restrictions apply to the unit Never use the unit to filter fluids other than water Do not use for commercial or industrial purposes Do not use in conjunc...

Page 7: ...moval of solid matter up to a particle size of 800 microns from the pond water Module M 3 foam filter Module M 3 foam filter ensures the mechanical and biological cleaning of pond water The pores of the foam inserts for a large internal surface for micro organisms to adhere to The foam inserts are of different densities In this manner zones are created causing the water to flow at different speeds...

Page 8: ...ons It is not permitted to install units operated with a rated voltage of 230 V in swimming ponds Observe a minimum distance between units and pond e g in Germany 2 m in Switzerland 2 5 m etc that the inlet sockets must be located below the pond water level such that the minimum water level in the container is 630 mm above the pit bottom A 3 Otherwise the pond water cannot drain and cleaned in the...

Page 9: ... which are not required properly closed Attention The unit is heavy Possible consequence Lifting and carrying the unit could put considerable strain on your cardiovascular and musculoskeletal system Protective measure Only lift and carry the unit with the help of a second person Inlet installation on the first filter module C Principle of gravity Connection of filter modules M 2 M 3 M 4 Figure sho...

Page 10: ...et at the pump chamber M1 outlet To avoid pressure loss minimise the length of the hose connection having a largest possible internal diameter without bends and well protected then saw off the stepped hose nozzle at the appropriate points for the individual hose Heat the hoses in hot water push or screw onto the stepped hose nozzle and secure with a hose clip Pumped systems Connect a DN 100 pipe t...

Page 11: ... of the dirt drain and wait until the pond water has drained and the containers are empty Fit a fresh water hose to the spray system except M 1 and supply fresh water Once the con tainers are rinsed inside and the water has drained firmly close the slide again and fill the containers with fresh water up to the drain level Once the cleaning process is completed reopen the slide at the system inlet ...

Page 12: ...ment volumen Antal filtre blå rød sort Vandtemperaturen NO Modul Mål Vekt Innganger Utganger Gjennomstrømning maksimal optimal Smussavløp Antall forfilter Volum for filterelementene Antall filter blå rød svart Vanntemperatur SE Modul Mått Vikt Ingångar Utgångar Genomströmning maximal optimal Smutsavlopp Antal förfilter Filterelementens volym Antal filter blå röd svart Vattentemperatur FI Moduuli M...

Page 13: ...филтри синьо червено черно Температурата на водата UA Модуль Розміри Вага Входи Виходи Проток максимальний оптимальний Стік для брудної води Кількість фільтрів попереднього очищення Об єм фільтрувальних елементів Кількість фільтрів синій червоний чорний Температура води RU Модуль Размеры Вес Входы Выходы Проток максимальный оптимальный Сток грязи Количество фильтров предварительной чистки Объем фи...

Page 14: ... 19 Luftanschluss Air connection Raccord d air Luchtaansluiting Conexión de aire Conexão para fornecimento de ar Allacciamento aria Lufttilslutning 20 Wasserstands anzeige Water level indicator Niveau d eau Waterpeil indicatie Indicador del nivel de agua Indicador de nível de água Indicatore livello dell acqua Vandstands visning 21 Thermometer mit Stütze Thermometer with support Thermomètre avec s...

Page 15: ...Lufttilkobling Luftanslutning Ilmaliitäntä Levegő csatlakozás Przyłącze powietrza Přípojka vzduchu Prípojka vzduchu Zračni priključek 20 Vannstand indikator Vattenmätare Vesitason mittari Vízszintjelző Wskaźnik poziomu wody Ukazatel stavu vody Ukazateľ stavu vody Vodokaz 21 Termometer med støtte Termometer med stöd Lämpömittari ja tuki Hőmérő felfogatással Termometr ze wspornikiem Teploměr s podpě...

Page 16: ...ак Внутрішня кришка Внутренняя крышка 内盖 19 Prikljuak zraka Racord pentru aer връзка за въздух Повітряне підключення Подсоединение воздуха 空气连接管 20 Prikaz razine vode Indicator de nivel al apei индикатор за нивото на водата Індикатор рівня води Индикация уровня воды 水位计 21 Termometar s potporom Termometru cu reazem термометър с опора Термометр з опорою Термометр с опорой 带支架的温度计 22 Bitron drža opc...

Page 17: ...143 ...

Page 18: ...144 ...

Page 19: ...145 ...

Page 20: ...146 ...

Page 21: ...30718 11 13 ...

Reviews: